Advanced menu, available only from the Power Wave Manager:
Table 8. List of Secured Parameters accessible through Power Wave Manager only.
P501
Encoder Lockout
Locks one or both of the upper Controls, preventing the operator from
changing wire feed speed, amps, volts or trim. The function of each upper
Control depends on the selected weld mode.
"Both Encoders Unlocked" (factory default) = The Left and the Right Control
is unlocked.
"Both Encoders Locked" = The Left and the Right Control is locked.
"Right Encoder Locked" = The Right Control is locked.
"Left Encoder Locked" = The Left Control is locked.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a
Mode Select Panel selection is locked and an attempt is made to change
that parameter, a message will be displayed on the display indicating the
parameter is locked.
"All MSP Options Unlocked" (factory default) = All adjustable parameters on
the Mode Select Panel are unlocked.
"All MSP Options Locked" = All Controls and buttons on the Mode Select
Panel are locked.
"Start & End Options Locked" = The Start and End parameters on the Mode
Select Panel are locked, all others are unlocked.
"Weld Mode Option Locked" = The weld mode cannot be changed from the
Mode Select Panel, all others Mode Select Panel settings are unlocked.
"Wave Control Options Locked" = The Wave Control parameters on the
Mode Select Panel are locked, all others are unlocked.
"Start, End, Wave Options Locked" = The Start, End and Wave Control
parameters on the Mode Select Panel are locked, all others are unlocked.
"Start, End, Mode Options Locked" = The Start, End and Weld Mode Select
parameters on the Mode Select Panel are locked, all others are unlocked.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without
entering a passcode.
"NO" (factory default)= The operator can change any set menu parameter
without first entering the passcode even if the passcode is non-zero (0000).
"YES" = The operator must enter the passcode (if the passcode is non-zero)
in order to change any setup menu parameters.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P506
Set User Interface
Passcode
Prevents unauthorized changes to the equipment. The default passcode is
0000 which allows full access. A nonzero passcode will prevent
unauthorized:
Changes to memory limits, saving to memory (if P.502 = Yes).
Changes to setup parameters (if P.505 = Yes).
Note:
This parameter can only be accessed using PowerWave Manager
software.
P509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any
changes.
Note:
This parameter can only be accessed using PowerWave Manager
software.