Lincoln Electric K14104-1 Скачать руководство пользователя страница 7

English 5 English 

Safety 

11/04 

 

WARNING

 

This equipment must be used by qualified personnel.  Be sure that all installation, operation, maintenance and repair 
procedures are performed only by qualified person.  Read and understand this manual before operating this equipment.  
Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment.  
Read and understand the following explanations of the warning symbols.  Lincoln Electric is not responsible for damages 
caused by improper installation, improper care or abnormal operation. 
 

 

WARNING:  This symbol indicates that instructions must be followed to avoid serious personal injury, loss 
of life, or damage to this equipment.  Protect yourself and others from possible serious injury or death. 

 

READ AND UNDERSTAND INSTRUCTIONS:  Read and understand this manual before operating this 
equipment.  Arc welding can be hazardous.  Failure to follow the instructions in this manual could cause 
serious personal injury, loss of life, or damage to this equipment. 

 

ELECTRIC SHOCK CAN KILL:  Welding equipment generates high voltages.  Do not touch the electrode, 
work clamp, or connected work pieces when this equipment is on.  Insulate yourself from the electrode, 
work clamp, and connected work pieces. 

 

ELECTRICALLY POWERED EQUIPMENT:  Turn off input power using the disconnect switch at the fuse 
box before working on this equipment.  Ground this equipment in accordance with local electrical 
regulations. 

 

ELECTRICALLY POWERED EQUIPMENT:  Regularly inspect the input, electrode, and work clamp 
cables.  If any insulation damage exists replace the cable immediately.  Do not place the electrode holder 
directly on the welding table or any other surface in contact with the work clamp to avoid the risk of 
accidental arc ignition. 

 

ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS:  Electric current flowing through any 
conductor creates electric and magnetic fields (EMF).  EMF fields may interfere with some pacemakers, 
and welders having a pacemaker shall consult their physician before operating this equipment. 

 

CE COMPLIANCE:  This equipment complies with the European Community Directives. 

 

FUMES AND GASES CAN BE DANGEROUS:  Welding may produce fumes and gases hazardous to 
health.  Avoid breathing these fumes and gases.  To avoid these dangers the operator must use enough 
ventilation or exhaust to keep fumes and gases away from the breathing zone. 

 

ARC RAYS CAN BURN:  Use a shield with the proper filter and cover plates to protect your eyes from 
sparks and the rays of the arc when welding or observing.  Use suitable clothing made from durable 
flame-resistant material to protect you skin and that of your helpers.  Protect other nearby personnel with 
suitable, non-flammable screening and warn them not to watch the arc nor expose themselves to the arc. 

Содержание K14104-1

Страница 1: ...IM3043 12 2020 REV03 LINC 406 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu...

Страница 2: ...he table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Number Date Where Purchased ENGLISH INDEX Technic...

Страница 3: ...sed on a 10 min period Output Current Output Voltage LINC 406 35 400 A 36 Vdc 60 315 A 32 6 Vdc 100 240 A 29 6 Vdc OUTPUT RANGE Welding Current Range Peak Open Circuit Voltage LINC 406 30A 400A 74 Vdc...

Страница 4: ...doesn t have idle state The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 20XX Manufacturer s name product na...

Страница 5: ...process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may...

Страница 6: ...work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the constru...

Страница 7: ...MENT Turn off input power using the disconnect switch at the fuse box before working on this equipment Ground this equipment in accordance with local electrical regulations ELECTRICALLY POWERED EQUIPM...

Страница 8: ...pors will be present Never operate this equipment when flammable gases vapors or liquid combustibles are present WELDED MATERIALS CAN BURN Welding generates a large amount of heat Hot surfaces and mat...

Страница 9: ...der can operate the machine at rated welding current Example 60 duty cycle Welding for 6 minutes Break for 4 minutes Excessive extension of the duty cycle will cause the thermal protection circuit to...

Страница 10: ...ent from the machine Welding Current 2 to the K10095 1 15M or K870 and vice versa 9 HOT START Control Value in percentage of nominal value welding current during arc start current The control is used...

Страница 11: ...onnel will cause that the manufacturer s warranty will become null and void Any noticeable damage should be reported immediately and repaired Routine maintenance everyday Check condition of insulation...

Страница 12: ...or any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such info...

Страница 13: ...First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communicat...

Страница 14: ...with lead 5m GRD 600A 95 5M Work Lead with the Work Clamp 5m FL060583010 FLAIR 600 Gouging torch with mounted monocable 2 5m N B 600A 95 5M Extension cable for gouging torch 5m K10095 1 15M Hand Amptr...

Отзывы: