Lincoln Electric K126-10 Innershield Скачать руководство пользователя страница 18

D-1

MAINTENANCE

D-1

K126-[ ] INNERSHIELD® PRO

NOTE: The maximum wire size for a K466-3 and K466-4

is 5/64”.  Therefore the 3/32” and 1/8” liners are not

included with these kits.

This screw should only be gently tightened.

Overtightening will split or collapse the liner and cause

poor wire feeding.

-------------------------------------------------------------------------------

     5. Be sure the cable is straight and then trim the liner

flush with the end of the gun tube.

     6. Remove the gun tube and trim an additional 9/16”

(12.7 mm) of material from the end of the liner (a 9/16”

gage is included on the wrench supplied with the gun).

     7. Replace the gun tube and tighten the clamping screw

to secure it.

     8. Reassemble the tip holder, insulator, and contact tip

onto the end of the gun tube.

GUN TUBES AND NOzzLES

     1. Replace worn contact tips as required.

     2. Remove spatter from from contact tip, tip holder, insu-

lator and gun tube after each 10 minutes of arc time or

as required.

     3. To remove gun tube from gun, loosen socket-head

clamping screw in handle with 3/16" (4.8 mm) Allen

wrench.  

     4. Pull gun tube out from gun handle.  To reinstall, insert

the gun tube, push in as far as possible, and retighten

clamping screw.

CABLE CLEANING

Clean cable liner after using approximately 150 (68 kg)

pounds of electrode.  Remove the cable from the wire feed-

er and lay it out straight on the floor.  Remove the contact tip

from the gun.  Using an air hose and only partial pressure,

gently blow out the cable liner from the tip holder end.

• Excessive pressure at the start may cause the dirt to

form a plug.

-------------------------------------------------------------------------------

Flex the cable over its entire length and again blow out the

cable.  Repeat this procedure until no further dirt comes out.

CAUTION

CAUTION

GUN HANDLE

Liner

CABLE

TIP HOLDER

TIP

 INSULATOR

FEEDER END

CABLE HANDLE

BRASS CABLE

CONNECTOR

SET SCREW

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIGHT AGAINST BRASS CABLE CONNECTOR

LINER TRIM

LENGTH

9/16" (14.3 mm)

Figure D.1

REMOVAL, INSTALLATION AND TRIMMING

INSTRUCTIONS FOR  MAGNUM® LINERS 

NOTE:

The variation in cable lengths prevents the inter-

changeability of liners. Once a liner has been cut for a par-

ticular gun, it should not be installed in another gun, unless

it can meet the liner cut off length requirement. Liners are

shipped with the jacket of the liner extended the proper

amount.

     1. Remove the insulator and tip holder.

     2. Lay the gun and cable straight on a flat surface.

     For all connectors except K466-3, K466-4 and K613-3: 

     Loosen set screw located in the brass cable connector at

the wire feeder end of the cable using the same 5/64

(2.0 mm) Allen wrench.  Pull liner out of cable.  

     

<OR>

     For K466-3, K466-4 and K613-3 connectors:

     Remove the connector cap with the wrench provided.

Pull liner out of cable.  If the liner is going to be replaced

with a different size liner, loosen set screw on the con-

nector cap and remove piece of liner material.

     3. Insert a new untrimmed liner into the connector end of

the cable.  Be sure the liner bushing is stenciled

appropriately for the wire size being used.

     4. Be sure to fully seat the liner bushing in the connector

and:

     For all connector kits except K466-3, K466-4 and K613-

3, tighten the set screw in the cable connector.

     

<OR>

     For K466-3, K466-4 and K613-3, screw in the connector

cap provided in the kit until it seats on the face of the

bushing.  Then insert the appropriate piece of liner mate-

rial into the connector cap and tighten the set screw.

Three pieces of liner material are included in these con-

nector kits to help guide the electrode through the con-

nector cap.  The piece with the smallest inner diameter is

designed for .045" (1.2 mm) maximum diameter elec-

trode and the other liners fit the following wires (maxi-

mum size) in order of increasing inside diameter:  1/16”

(1.6 mm), 5/64” (2.0 mm), 3/32” (2.4 mm) and 1/8” (3.2

mm). 

Содержание K126-10 Innershield

Страница 1: ...ric com register Authorized Service and Distributor Locator www lincolnelectric com locator IM10045 B Issue Date Sept 12 Lincoln Global Inc All Rights Reserved For use with machines having Code Number...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...rs and devices in position and in good repair Keep hands hair clothing and tools away from V belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some case...

Страница 4: ...to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with su...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...________________________________________________________ Accessories Section C Wire Feeder Connection Kits C 1 Gun Consumable Parts C 2 ________________________________________________________________...

Страница 7: ...7 NOTES K126 INNERSHIELD PRO 7...

Страница 8: ...85 F 40C to 85C Cable Length 10ft 3 0m 15ft 4 5m Weight 7 3 lbs 3 3 kg 11 lbs 5 kg Electrode Diameter Range 035 3 32 0 8 2 4 mm Output Range Amperes 260A 100 duty cycle 350A 60 duty cycle Wire Feed Sp...

Страница 9: ...X Trigger Lead Connector X X X X X X X X X Gas Tube and Fitting X X X Connector Tools X X X X X X X X X X Wire Feeder Connector Kits up to 5 64 diameter wire Note These kits must be used with the KP4...

Страница 10: ...t 072 1 9 KP2745 072R K126 11 4 5 3 32 2 4 KP2745 332R KP2908 1 KP2907 1 KP45H 322 15 KP2906 62 K613 1 15 ft 072 1 9 KP2745 072R K126 12 4 5 5 64 2 0 KP2745 564R KP2908 1 KP2907 1 KP44 564 15 KP2906 6...

Страница 11: ...as the drive roll are appropriate for the electrode size being used On Lincoln feeders check that the K1500 2 gun adapter is in place 2 Fully push the brass connector end of the gun cable into the br...

Страница 12: ...plug to the proper receptacle on the machine K466 6 K466 7 and K466 9 Installation Wirematic Hobart Series 2000 Feeders SP100T Type and Power MIG 1 Remove brass cable connector see Figure A 2 from the...

Страница 13: ...a 9 16 gage is included on the wrench supplied with the gun 7 Replace the gun tube and tighten the clamping screw to secure it 8 Reassemble the tip holder insulator and contact tip onto the end of the...

Страница 14: ...adapter and feeder outgoing guide as well as the drive rolls are appropriate for the electrode size being used 2 Fully push the brass connector end of the gun cable into the outgoing side of the feede...

Страница 15: ...perate this equipment 1 Check that the welding power source is on 2 Position electrode over joint End of the electrode should be slightly off the work 3 Lower welding helmet close gun trigger and begi...

Страница 16: ...K613 2 K613 3 K613 4 K613 5 none Model LN 7 LN 8 LN 9 series LN 25 0 052 max LN 742 LN 7 LN 8 LN 9 series LN 25 1 16 and larger LN 742 LF 72 LN 74 Series 10 feeders LN 15 PF 10M PF 15M Power MIG Wirem...

Страница 17: ...16 0 068 0 072 5 64 3 32 10 piece pack KP2745 035R KP2745 045R KP2745 052R KP2745 116R KP2745 072R KP2745 072R KP2745 564R KP2745 332R 100 piece pack KP2745 035R B100 KP2745 045R B100 KP2745 052R B10...

Страница 18: ...ER BUSHING TO BE SEATED TIGHT AGAINST BRASS CABLE CONNECTOR LINER TRIM LENGTH 9 16 14 3 mm Figure D 1 REMOVAL INSTALLATION AND TRIMMING INSTRUCTIONS FOR MAGNUM LINERS NOTE The variation in cable lengt...

Страница 19: ...SIBLE CAUSE lists the obvious external possi bilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause gene...

Страница 20: ...ine s wire feed speed setting is too low 3 Wire is obstructed somewhere along the wire feed path in the gun 4 Low motor voltage 5 Gun cable is coiled kinked 6 Mechanical resistance to wire feeding is...

Страница 21: ...ample ESO is too short 2 Wire may be feeding inter mittently 1 Improper electrode polarity 2 Improper welding parameters or technique 1 Defective trigger contacts closed or dirty 2 Defective closed tr...

Страница 22: ...ve parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa mojada l Aislese del trabajo y de la tierr...

Страница 23: ...nd Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de alimentac...

Страница 24: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or...

Отзывы: