Lincoln Electric K126-10 Innershield Скачать руководство пользователя страница 10

A-3

INSTALLATION   

K126-[ ] INNERSHIELD® PRO

A-3

The K126 Innershield Pro has stainless steel jacketed

goosenecks for extended life.  The goosenecks are

similar in structure to a MIG gun gooseneck.  A

copper tube is used for the conductor and a stainless

steel tube is used for the outer jacketing, while a

Teflon tube acts as an insulator between the copper

and steel.  The replaceable spring liner extends

through the gooseneck, so that the wire is

continuously supported throughout the gun. 

The K126 Innershield Pro gun utilizes a replaceable

connector assembly at the feeder end of the gun so

that the gun can be easily used with any feeder.

These connectors are the same K466/K613 kits used

with the Magnum MIG gun product line. 

RECOMMENDED PROCESSES AND

EQUIPMENT

RECOMMENDED PROCESSES

• FCAW-SS

PROCESS LIMITATIONS

• This gun can only be used with self-shielded wires.

The design will not support the use of shielding gas.

EQUIPMENT LIMITATIONS

• The K126 Pro will not operate with the LN23P

feeder.

• The K126 Pro does not support the 83% reduced

feed speed switch for pipe welding.

  Description

                              Gun                                                                                                                                                                    Feeder End

  Product             Cable          Wire Size      Contact Tips       Tip Holder         Insulator         Cable Liner        Gun Tube       Connector

  Number         Length (m)       in. (mm)                                                                                                                                           Assembly

  

                              10 ft

.072 (1.9)      KP2745-072R

  K126-10               (3.0)

3/32 (2.4)      KP2745-332R        KP2908-1          KP2907-1      KP45H-322-15     KP2906-62          K613-1     

                              15 ft

.072 (1.9)      KP2745-072R

  K126-11               (4.5)

3/32 (2.4)      KP2745-332R        KP2908-1          KP2907-1      KP45H-322-15     KP2906-62          K613-1     

                              15 ft

.072 (1.9)      KP2745-072R

  K126-12               (4.5)

5/64 (2.0)      KP2745-564R        KP2908-1          KP2907-1       KP44-564-15      KP2906-62          K466-1

                              15 ft

.072 (1.9)      KP2745-072R

  K126-13               (4.5)

5/64 (2.0)      KP2745-564R        KP2908-1          KP2907-1       KP44-564-15       KP3267-1           K613-6

K126 INNERSHIELD PRO

350 AMPERES @ 60% DUTY CYCLE

GENERAL DESCRIPTION

• Do not touch electrically live parts

such as output terminals or internal

wiring

------------------------------------------------------------------------

The K126 Innershield Pro gun and cable assemblies

have been designed specification for welding with mild

steel FCAW-S (self-shielded flux cored) processes.

The K126 Pro product is designed for extended life

and improved wire feeding in heavy duty welding

applications.

The K126 Innershield Pro products use a cable with a

core made from flat wound spring steel.  The copper

conductors which transmit welding current are

wrapped around the spring core.  Four #20 insulated

leads are wrapped along with the copper conductors

for use in the gun trigger circuit.  The cable jacketing

is made from a cross linked polymer which provides

exceptional heat resistance and fatigue life.

A round wound spring steel liner is then placed inside

the spring core of the cable to contain the wire while it

is being transported to the welding arc.  This liner is

replaceable so that it can be sized correctly for the

welding wire being used, and it can be removed and

replaced with a new liner as it wears out.  Both of

these features improve the feeding of the wire through

the gun.

WARNING

Содержание K126-10 Innershield

Страница 1: ...ric com register Authorized Service and Distributor Locator www lincolnelectric com locator IM10045 B Issue Date Sept 12 Lincoln Global Inc All Rights Reserved For use with machines having Code Number...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...rs and devices in position and in good repair Keep hands hair clothing and tools away from V belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some case...

Страница 4: ...to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with su...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...________________________________________________________ Accessories Section C Wire Feeder Connection Kits C 1 Gun Consumable Parts C 2 ________________________________________________________________...

Страница 7: ...7 NOTES K126 INNERSHIELD PRO 7...

Страница 8: ...85 F 40C to 85C Cable Length 10ft 3 0m 15ft 4 5m Weight 7 3 lbs 3 3 kg 11 lbs 5 kg Electrode Diameter Range 035 3 32 0 8 2 4 mm Output Range Amperes 260A 100 duty cycle 350A 60 duty cycle Wire Feed Sp...

Страница 9: ...X Trigger Lead Connector X X X X X X X X X Gas Tube and Fitting X X X Connector Tools X X X X X X X X X X Wire Feeder Connector Kits up to 5 64 diameter wire Note These kits must be used with the KP4...

Страница 10: ...t 072 1 9 KP2745 072R K126 11 4 5 3 32 2 4 KP2745 332R KP2908 1 KP2907 1 KP45H 322 15 KP2906 62 K613 1 15 ft 072 1 9 KP2745 072R K126 12 4 5 5 64 2 0 KP2745 564R KP2908 1 KP2907 1 KP44 564 15 KP2906 6...

Страница 11: ...as the drive roll are appropriate for the electrode size being used On Lincoln feeders check that the K1500 2 gun adapter is in place 2 Fully push the brass connector end of the gun cable into the br...

Страница 12: ...plug to the proper receptacle on the machine K466 6 K466 7 and K466 9 Installation Wirematic Hobart Series 2000 Feeders SP100T Type and Power MIG 1 Remove brass cable connector see Figure A 2 from the...

Страница 13: ...a 9 16 gage is included on the wrench supplied with the gun 7 Replace the gun tube and tighten the clamping screw to secure it 8 Reassemble the tip holder insulator and contact tip onto the end of the...

Страница 14: ...adapter and feeder outgoing guide as well as the drive rolls are appropriate for the electrode size being used 2 Fully push the brass connector end of the gun cable into the outgoing side of the feede...

Страница 15: ...perate this equipment 1 Check that the welding power source is on 2 Position electrode over joint End of the electrode should be slightly off the work 3 Lower welding helmet close gun trigger and begi...

Страница 16: ...K613 2 K613 3 K613 4 K613 5 none Model LN 7 LN 8 LN 9 series LN 25 0 052 max LN 742 LN 7 LN 8 LN 9 series LN 25 1 16 and larger LN 742 LF 72 LN 74 Series 10 feeders LN 15 PF 10M PF 15M Power MIG Wirem...

Страница 17: ...16 0 068 0 072 5 64 3 32 10 piece pack KP2745 035R KP2745 045R KP2745 052R KP2745 116R KP2745 072R KP2745 072R KP2745 564R KP2745 332R 100 piece pack KP2745 035R B100 KP2745 045R B100 KP2745 052R B10...

Страница 18: ...ER BUSHING TO BE SEATED TIGHT AGAINST BRASS CABLE CONNECTOR LINER TRIM LENGTH 9 16 14 3 mm Figure D 1 REMOVAL INSTALLATION AND TRIMMING INSTRUCTIONS FOR MAGNUM LINERS NOTE The variation in cable lengt...

Страница 19: ...SIBLE CAUSE lists the obvious external possi bilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause gene...

Страница 20: ...ine s wire feed speed setting is too low 3 Wire is obstructed somewhere along the wire feed path in the gun 4 Low motor voltage 5 Gun cable is coiled kinked 6 Mechanical resistance to wire feeding is...

Страница 21: ...ample ESO is too short 2 Wire may be feeding inter mittently 1 Improper electrode polarity 2 Improper welding parameters or technique 1 Defective trigger contacts closed or dirty 2 Defective closed tr...

Страница 22: ...ve parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa mojada l Aislese del trabajo y de la tierr...

Страница 23: ...nd Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de alimentac...

Страница 24: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or...

Отзывы: