V300-PRO
TROUBLESHOOTING & REPAIR
F-62
F-62
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
RETEST AFTER REPAIR
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could
affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine
must be retested.
NOTE: 50 Hz machines may be tested using 60 Hz power.
INPUT IDLE AMPS AND IDLE WATTS
Input
Single Phase
Three Phase
Volts/Hertz
Max. Amps
Max. Watts
Max. Amps
Max. Watts
220/50 or 60
2.75
425
2.75
425
230/60
3.00
450
3.00
450
440/50 or 60
1.38
425
460/60
1.50
450
380/50 or 60
1.67
425
575/60
—
—
OCV at rated INPUT: V300-PRO, V300-I
60-75V
MAXIMUM ACCEPTABLE OUTPUT AMPS (AT MINIMUM OUTPUT SETTINGS)
Output
Min. (Max. acceptable), all machines:
CC modes
12A @ 10V.
(GTAW, SOFT, CRISP)
CV modes
20A @ 19V.
(FCAW, GMAW)
OUTPUT MINIMUM ACCEPTABLE VOLTS (AT MAXIMUM OUTPUT SETTINGS,
WITH FULL LOAD)
Min. Acceptable,
Max. — All Modes
V300-I
V300-PRO
1 phase @ 200A
380V
220/440V
208V
230/460V
575V
—
38V
—
38V
36V
3 phase @ 300A
32V
36V
34V
38V
36V
AUXILIARY TRANSFORMER — 50 Hz or 60 Hz
TEST POINTS
RANGE
18 VAC winding to Power Board J7 pins 5 and 6 Welding
17-20 VAC
terminals sw. remote
24 VAC winding to Control Board J2 pin 4 to lead 212
23-26.5 VAC
STANDARD CODES: (Test at Amphenol)
24 VAC without load, measure across pins C and D
22-25 VAC
42 VAC without load, measure across pins I and K
39-44 VAC
115 VAC without load, measure across pins A and J
109-120 VAC