V300-PRO
OPERATION
B-2
B-2
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
OPERATING INSTRUCTIONS
DUTY CYCLE
The Invertec is rated at 300 amps, 60% duty cycle for
3 phase inputs (based on a 10 minute cycle). It is also
rated at 250 amps, 100% duty cycle.
CONTROL FUNCTION / OPERATION
POWER SWITCH - Place the lever in the “ON” position
to energize the machine. When the power is on, the
digital meter will activate and the fan will operate.
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove
fumes from breathing zone.
-------------------------------------------------------
-----------------
WELDING SPARKS can cause fire or
explosion.
• Keep flammable material away.
• Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body
protection.
------------------------------------------------------------
See additional warning information at
front of this operator’s manual.
-----------------------------------------------------------
WARNING
OUTPUT CONTROL - This controls the output voltage
in the CV modes and output current in the CC modes.
Control is provided over the entire output range of the
power source with 1 turn of the control knob. This con-
trol may be adjusted while under load to change power
source output.
LOCAL/REMOTE SWITCH - Place in the “LOCAL”
position to allow output adjustment at the machine.
Place in the “REMOTE” position to allow output adjust-
ment at the wire feeder or with a remote control option
package.
DIGITAL METER SWITCH - Select either “A” for amps
or “V” for volts to display welding current or voltage on
the meter.
When welding current is not present, the meter will dis-
play the set current for the CC modes or the set volt-
age for the CV modes. This set reading is an indication
of machine control setting. For a more precise process
reading, read meter during actual welding.
.
OUTPUT
REMOTE
OFF