A-7
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
WARNING
The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations,
due to conducted as well as radio-frequency disturbances.
Technical Specifications
V205-T AC/DC:
INPUT
Input Voltage
115/230 V
15%
Single Phase
Input Power at Rated Output
6.6 kW @ 40% Duty Cycle
Frequency
50/60 Hz
RATED OUTPUT AT 40°C
Duty Cycle
(Based on a 10 min. period)
40% TIG 115/230 V
60% TIG 115/230 V
35% MMA 115/230 V
60% MMA 115/230 V
Output Current
150/200 A
120/170 A
110/180 A
90/150 A
Output Voltage
16.0/18.0 Vdc
14.8/16.8 Vdc
24.4/27.2 Vdc
23.6/26.0 Vdc
OUTPUT RANGE
Welding Current Range
6-200 A
Maximum Open Circuit Voltage
53.7 Vdc
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or Circuit Breaker Size
16 A Superlag
Type of Plug
SCHUKO 16A/250V
(Included with Machine)
Input Power Cable
3 Conductor, 2.5 mm
2
PHYSICAL DIMENSIONS
Height
385 mm
Width
215 mm
Length
480 mm
Weight
17.6 Kg
Operating Temperature
–20°C to +40°C
Storage Temperature
-25°C to +55°C
V305-T AC/DC:
INPUT
Input Voltage
400 V
15%
Three Phase
Input Power at Rated Output
11.8kW @ 40% Duty Cycle
Frequency
50/60 Hz
RATED OUTPUT AT 40°C
Duty Cycle
(Based on a 10 min. period)
40%
60%
Output Current
300 A
250 A
Output Voltage
32.0 Vdc
30.0 Vdc
OUTPUT RANGE
Welding Current Range
6-300 A
Maximum Open Circuit Voltage
81 Vdc
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or Circuit Breaker Size
20 A Superlag
Input Power Cable
4 Conductor, 6 mm
2
PHYSICAL DIMENSIONS
Height
500 mm
Width
275 mm
Length
610 mm
Weight
33 Kg
Operating Temperature
–20°C to +40°C
Storage Temperature
-25°C to +55°C
Содержание INVERTEC V205-T AC/DC TIG