A -
3
INSTALLATION
A-3
INVERTEC
®
CV/CC500
Rev. 03
PROCESS SELECTIONS AND
CONNECTIONS
ELECTRIC SHOCK can kill.
Only qualified personnel
should perform this
installation.
Turn the input power OFF at
the main switch or fuse box before working on
this equipment. Turn off the input power to any
other equipment connected to the welding
system at the main switch or fuse box before
working on the equipment.
Do not touch electrically
“Hot” parts.
Always connect the INVERTEC
®
grounding lug
(located at the rear of the case) to a proper safety
(Earth) ground.
INVERTEC
®
is for use on a 4 wire
system with earthed neutral.
WORK CONNECTION
Connect a work lead of sufficient size between the
proper output stud on the power source and the work.
Be sure the connection to the work makes tight metal to
metal electrical contact. Poor work lead connections
can result in poor welding performance.
To avoid interference problems with other equipment
and to achieve the best possible operation, route all
cables directly to the work and wire feeder. Avoid
excessive lengths and do not coil excess cable.
Cable sizes are increased for greater lengths primarily
for the purpose of minimizing cable drop.
Minimum work and electrode cable sizes are as follows:
TABLE A.1
Current (60% Duty Cycle)
Minimum Copper
Work Cable Size
200A
300A
400A
500A
Up To 30m Length
30 mm
2
50 mm
2
70 mm
2
95 mm
2
Note: The recommended cable size may need to
change depending on its quality. When the rated
current flow goes through, the total voltage drop on
ground cable and electrode cable must not exceed 4
volts.
GMAW PROCESS ( CV MODE ) WIRE FEEDER CONNECTION
1. PWF WIRE FEEDER
(
FIGURE A.3 )
WELDING CABLE
NEGATIVE
STUD
-
+
POSITIVE
STUD
WIRE
FEEDER
CONNECTOR
REMOTE
CONTROL
CONNECTOR
INVERTEC CV/CC WELDER
R
WELDING TORCH
GAS HOSE
GAS REGUL ATOR
ELECTRODE
PWF WIRE FEEDER
WORK
WORK CLAMP
CONTROL CABLE
SHIELDING GAS
CYLINDER
FIGURE A.3
WARNING
Содержание Invertec CC500
Страница 13: ...B 3 OPERATION B 3 INVERTEC CV CC500 Rev 03 FIGURE B 3 FIGURE B 4...
Страница 15: ...B 5 OPERATION B 5 INVERTEC CV CC500 Rev 03 FIGURE B 6...
Страница 19: ...E 1 Parts List E 1 INVERTEC CV CC500 Rev 03...
Страница 20: ...E 2 Parts List E 2 INVERTEC CV CC500 Rev 03...
Страница 21: ...E 3 Parts List E 3 INVERTEC CV CC500 Rev 03...