Lincoln Electric INVERTEC 275TP Скачать руководство пользователя страница 19

English 17 English 

Accessories 

 
Accessories and torches configuration can be accessed 
from the Home Menu by pushing knob button and 
selected “Remote Control” icon and push knob again. 
 

 

 
When activated, a new icon appears on the right of 
“Remote Control” icon named “Remote range”. 
 

 

 

Hand Remote 

Usable for GTAW and SMAW process. 
 
The current displayed correspond to the position of the 
remote control potentiometer from minimum to maximum 
current. 
 
Minimum and maximum can be defined in the “Remote 
Range”. In above example, the minimum current is 5A 
and the maximum is 270A for GTAW and 250A for 
SMAW  
 

Foot Pedal 

Usable in GTAW only. 
 
When selected, the maximum current is the one set on 
“Home” page by the knob. The minimum current is, like 
“Hand Remote”, the one set on Remote Range section. 
 
As much the pedal is pushed, as much the current will 
decrease. 
 

Potentiometer Torch 

Usable in GTAW and SMAW 
 
“Potentiometer torch” has the same behavior than “Foot 
Pedal” 
 

Amperage UP-DOWN Torch 

Usable in GTAW only. 
 
Three operating modes, corresponding to different states 
of the machine, are identified: 

  Before welding: pressing the UP or DOWN key 

causes a change of value of the Set current 

  While welding: pressing the UP or DOWN key causes 

a change of  value of the Set current during all 
phases of welding process except during the start 
functions, where the UP/DOWN function is masked. 

  Pre/post Flow: pressing the UP or DOWN key causes 

a change of value of the Set current. 

 
The change will be realized in two ways depending on 
pressed button time: 

 Step 

function 

Pressing the UP/DOWN button for a minimum time of 
200ms and releasing it, causes the set current 
raises/falls of 1A. 

 Ramp 

function 

 

Pressing the UP/DOWN button for a time greater 
than 1 sec., the set current start to increase/decrease 
with a (5A/s) ramp. If press for more than 5 sec 
increase/decrease with a ramp of (10A/s). 

The current ramp will end when the UP/DOWN button 
previously pressed is released. 
 

Содержание INVERTEC 275TP

Страница 1: ...IM3136 09 2021 REV02 INVERTEC 275TP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu...

Страница 2: ...enter your product identification data in the table below Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased INDEX Technical Spec...

Страница 3: ...0 180A 60 230A 35 250A OUTPUT RANGE Welding Current Range Peak Open Circuit Voltage U0 GTAW 5 270A 72V SMAW 5 250A DIMENSIONS AND WEIGHT Weight Height Width Length INVERTEC 275TP 16 kg 360 mm 230 mm 4...

Страница 4: ...de X STICK mode After 30 minutes of non working X Fan off X The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1...

Страница 5: ...into the welding pool Notice A cross wind or draft moving can disrupt the shielding gas coverage in the interest of saving of protective gas use screen to block air flow End of life At end of life of...

Страница 6: ...or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipme...

Страница 7: ...cordance with local electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do n...

Страница 8: ...to a fixed support Do not move or transport gas cylinders with the protection cap removed Do not allow the electrode electrode holder work clamp or any other electrically live part to touch a gas cyl...

Страница 9: ...er than 40 C Duty cycle and Overheating The duty cycle of a welding machine is the percentage of time in a 10 minute cycle at which the welder can operate the machine at rated welding current Example...

Страница 10: ...ecting a Remote Control Kit 6 User Interface See User Interface section 7 USB connector Back panel INVERTEC 275TP Figure 2 1 Gas quick coupling socket For connecting a gas pipe 2 Power switch WARNING...

Страница 11: ...Soft Crisp etc If Guided Setup Mode is selected all inputs will be displayed in the section 2 Status Bar give additional information like Trigger Interlock selection remote control status 3 Preset Cur...

Страница 12: ...dicated Section Configure Parameters Arc Strike Figure 7 To select the type of arc striking HF or Touch Start select the corresponding menu and push the Knob Figure 8 Select the arc strike type desire...

Страница 13: ...trigger mode and a TIG welding mode selected the following welding sequence will occur 1 Press and hold the TIG torch trigger to start the sequence The machine will open the gas valve to start the fl...

Страница 14: ...rom the torch hose the output of the machine is turned ON At this time the arc is started according to the selected welding mode After the arc is started the output current will be at the Start curren...

Страница 15: ...the main part of the weld is complete go to step 3 As shown here again after the TIG torch trigger is quickly pressed and released from step 3A it is possible to quickly press and release the TIG torc...

Страница 16: ...a new icon will be present for time configuration Tack For Thin sequence Tack for Thin sequence is very identical to Spot sequence but ramp up and ramp down phases of weld sequence are not present Cur...

Страница 17: ...e 16 The machine allow the user the use 4 stick mode Soft For a welding with a low spatter presence Hot Start and Arc Force are pre defined and can not be modified Crisp For an aggressive welding with...

Страница 18: ...ddle that occur during normal stick welding Figure 18 Anti Sticking This feature cannot be modified by user This is a function that decreases the output current of the machine to a low level when the...

Страница 19: ...GTAW and SMAW Potentiometer torch has the same behavior than Foot Pedal Amperage UP DOWN Torch Usable in GTAW only Three operating modes corresponding to different states of the machine are identifie...

Страница 20: ...ng to be saved are displayed 2 With the knob it is possible to scroll up or down to select an empty or used slot memory If the slot is already used the parameters associated to the backup are displaye...

Страница 21: ...ll be adjusted by Adding list of all inputs data in Primary Settings section Preset a defined current value Modifying current range ribbon Primary settings To change and configure input parameters pre...

Страница 22: ...Vrd can be activated deactivated Configuration of Cooler System Information The software revision will be displayed in this section Software upgrade Software will be released during the life time of...

Страница 23: ...and lifting with a crane adhere to the following rules The device contains elements adapted for transport For lifting a suitable lifting equipment capacity WARNING In any way the power source cannot b...

Страница 24: ...or any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such info...

Страница 25: ...uding removal of accumulated dust and dirt from the intake and outlet louvers User interface show information when machine will be cooled down To continue welding operation Please press left knob or s...

Страница 26: ...First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communicat...

Страница 27: ...79 W000278922 WTT2 9 EB W000278875 WTT2 17 RL W000278884 W000278917 WTT2 17 EB W000278882 W000278919 WTT2 26 RL W000278890 W000278913 WTT2 26 EB W000278887 W000278915 TIG TORCHES WATER 4mt 8mt WTT2 18...

Отзывы: