Lincoln Electric FLEXTEC 450 CE Скачать руководство пользователя страница 8

English  

English 

4

 

Safety 

11/04 

 

WARNING

 

This equipment must be used by qualified personnel.  Be sure that all installation, operation, maintenance and repair 
procedures are performed only by qualified person.  Read and understand this manual before operating this equipment.  
Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this 
equipment.  Read and understand the following explanations of the warning symbols.  Lincoln Electric is not responsible 
for damages caused by improper installation, improper care or abnormal operation. 
 

 

WARNING:  This symbol indicates that instructions must be followed to avoid serious personal injury, 
loss of life, or damage to this equipment.  Protect yourself and others from possible serious injury or 
death. 

 

READ AND UNDERSTAND INSTRUCTIONS:  Read and understand this manual before operating 
this equipment.  Arc welding can be hazardous.  Failure to follow the instructions in this manual could 
cause serious personal injury, loss of life, or damage to this equipment. 

 

ELECTRIC SHOCK CAN KILL:  Welding equipment generates high voltages.  Do not touch the 
electrode, work clamp, or connected work pieces when this equipment is on.  Insulate yourself from 
the electrode, work clamp, and connected work pieces. 

 

ELECTRICALLY POWERED EQUIPMENT:  Turn off input power using the disconnect switch at the 
fuse box before working on this equipment.  Ground this equipment in accordance with local electrical 
regulations. 

 

ELECTRICALLY POWERED EQUIPMENT:  Regularly inspect the input, electrode, and work clamp 
cables.  If any insulation damage exists replace the cable immediately.  Do not place the electrode 
holder directly on the welding table or any other surface in contact with the work clamp to avoid the 
risk of accidental arc ignition. 

 

ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS:  Electric current flowing through any 
conductor creates electric and magnetic fields (EMF).  EMF fields may interfere with some 
pacemakers, and welders having a pacemaker shall consult their physician before operating this 
equipment. 

 

CE COMPLIANCE:  This equipment complies with the European Community Directives. 

 

FUMES AND GASES CAN BE DANGEROUS:  Welding may produce fumes and gases hazardous to 
health.  Avoid breathing these fumes and gases.  To avoid these dangers the operator must use 
enough ventilation or exhaust to keep fumes and gases away from the breathing zone. 

 

ARC RAYS CAN BURN:  Use a shield with the proper filter and cover plates to protect your eyes from 
sparks and the rays of the arc when welding or observing.  Use suitable clothing made from durable 
flame-resistant material to protect you skin and that of your helpers.  Protect other nearby personnel 
with suitable, non-flammable screening and warn them not to watch the arc nor expose themselves to 
the arc. 

 

WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION:  Remove fire hazards from the welding 
area and have a fire extinguisher readily available.  Welding sparks and hot materials from the welding 
process can easily go through small cracks and openings to adjacent areas.  Do not weld on any 
tanks, drums, containers, or material until the proper steps have been taken to insure that no 
flammable or toxic vapors will be present.  Never operate this equipment when flammable gases, 
vapors or liquid combustibles are present. 

 

WELDED MATERIALS CAN BURN:  Welding generates a large amount of heat.  Hot surfaces and 
materials in work area can cause serious burns.  Use gloves and pliers when touching or moving 
materials in the work area. 

 

SAFETY MARK:  This equipment is suitable for supplying power for welding operations carried out in 
an environment with increased hazard of electric shock. 

Содержание FLEXTEC 450 CE

Страница 1: ...IM2059 04 2014 REV01 FLEXTEC 450 650 CE OPERATOR S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St Clair Ave Cleveland Ohio 44117 1199 USA www lincolnelectric eu...

Страница 2: ...s Product numbers K3065 Product numbers may also contain prefixes and suffixes Is in conformity with Council Directives and amendments Electromagnetic Compatibility EMC Directive 2004 108 EC Low Volta...

Страница 3: ...duct numbers K3060 and K3129 Product numbers may also contain prefixes and suffixes Is in conformity with Council Directives and amendments Electromagnetic Compatibility EMC Directive 2004 108 EC Low...

Страница 4: ...e dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number D...

Страница 5: ...8 10 8 10 8 10 10 6 90 80 60 Output is limited to 600A 100 and 700A 60 when used with K3091 1 Multi Process Swith 1 Cord and Fuse Sizes based upon the U S National Electric Code and maximum output for...

Страница 6: ...3 60 415 3 60 42A 40A 39A 8 AWG or 10 mm 2 50 1 Cord and Fuse Sizes based upon the U S National Electric Code and maximum output for 40 C 104 ambient 2 Also called inverse time or thermal magnetic ci...

Страница 7: ...the work area for any devices that may malfunction because of electromagnetic disturbances Consider the following Input and output cables control cables and telephone cables that are in or adjacent to...

Страница 8: ...he work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fie...

Страница 9: ...ugh the rear louvers and out through the case sides Dirt dust or any foreign material that can be drawn into the welder should be kept at a minimum Failure to observe these precautions can result in e...

Страница 10: ...connection diagram located on the inside of the reconnect input access door of the machine Failure to do so may result in bodily injury or death Input Connection Use a three phase supply line For Fle...

Страница 11: ...utput studs of the FLEXTEC 650 450 per the following guidelines Most welding applications run with the electrode being positive For those applications connect the electrode cable between the wire driv...

Страница 12: ...This minimizes the possibility of interference between the high currents flowing through the weld cables and the low level signals in the control cables Paralleling only for Flextec 650 FLEXTEC 650 po...

Страница 13: ...en Circuit Voltage at the welding output terminals while not welding to less than 35VDC The machine is shipped with VRD enabled The VRD function can be disabled or enabled via a dip switch on the cont...

Страница 14: ...on Input voltage misconnection protection Utilizes digital signal processing and microprocessor control VRD Voltage Reduction Device Enable this function for reduced OCV in CC modes for added safety C...

Страница 15: ...4 6 pin remote circular connector 15 Positive and negative welding output studs 16 VRD Voltage Reduction Device Indicator lights Figure 5 Flextec 450 Case Back Control Desciptions for Flextec 650 see...

Страница 16: ...y Meter Prior to CV operation current flow the meter displays desired preset voltage value 5V only for Flextec 650 Prior to STICK or TIG operation the meter displays the Open Circuit Voltage of the Po...

Страница 17: ...hold period results in the prior to operation characteristics stated above The displays blink indicating that the machine is in the hold period GTAW This weld mode is a constant current CC mode featur...

Страница 18: ...d arc gouging Hot Start For Flextec 650 Rotate from the 0 position to the 10 position to provide more energy during the start of a weld Hot Start For Flextec 450 Toggle to ON position to provide more...

Страница 19: ...e 6 pin or 14 pin connectors the output is controlled through the Output Control Dial on the front of the FLEXTEC 650 Set this switch to REMOTE when an external potentiometer control is connected Outp...

Страница 20: ...t reading instructions Do not use this part list for a machine if its code number is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of a...

Отзывы: