![Lincoln Electric DC-600 series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/lincoln-electric/dc-600-series/dc-600-series_operators-manual_1918928022.webp)
REMOTE CONTROL OF MACHINE
OPERATION
The toggle switch on the control panel labeled
“Remote - Panel” gives the operator the option of con-
trolling the machine output from a remote location. If
in the Remote position a wire feeder with remote con-
trol capabilities or a remote control device such as a
K775 must be connected to terminals 75, 76, and 77.
Refer to Accessories Section for wire feeder remote
information.
WELDING PROCEDURE
RECOMMENDATIONS
Select Welding Mode Switch position based on type of
welding to be done.
1. Innershield Welding (FCAW)/MIG (GMAW)
Welding: Use the
CV INNERSHIELD
mode.
2. Submerged Arc Welding (SAW): Use the
CV
SUBMERGED ARC
mode. If performing high
speed welding, switch between the CV
Submerged Arc and the CV Innershield mode and
use the mode that produces the best welding
results.
3. Air/Carbon Arc Cutting (AAC) / Stick Welding
(SMAW) / High Current, Large Puddle Submerged
Arc Welding (SAW): Use the
CC STICK
mode.
When the DC-600 is used for Air/Carbon Arc cut-
ting, the OUTPUT CONTROL potentiometer
should be set to "9" initially. Based on the size of
the carbon being used or the process, turn the
potentiometer to a lower setting as required by the
process. You can use carbon rods up to 3/8" in
diameter at currents as high as 750 amps with
excellent arc control. The welder protection circuit
protects the machine from extremely high short
circuiting pulses.
SEMI-AUTOMATIC AND
AUTOMATIC WIRE FEEDING WITH
THE DC-600 AND WIRE FEEDERS
When using the DC-600 with semi-automatic or auto-
matic wire feeding equipment and for stick welding or
air/carbon arc cutting, it is recommended that the
optional MULTI-PROCESS SWITCH be used. This
switch permits you to easily change the polarity of the
connected wire feeding equipment or switch to stick
welding or air/carbon arc cutting.
B-6
OPERATION
B-6
The power source circuitry is protected from faults on
leads 75, 76, or 77. If any of these leads are connect-
ed to either the positive or negative output leads, the
DC-600 will either shut down completely (input con-
tactor opens and white POWER light stays illuminat-
ed), or will operate at minimum output thus preventing
any damage to the DC-600. If DC-600 shuts down, it
must be manually started by resetting the POWER
ON/OFF toggle switch.
OPERATING STEPS
The following procedures are for using the DC-600 in
the local control mode of operation. For remote con-
trol of the machine, see the Remote Control of
Machine Operation section.
Before operating the machine, make sure you have all
materials needed to complete the job. Be sure you
are familiar with and have taken all possible safety
precautions before starting work. It is important that
you follow these operating steps each time you use
the machine.
1. Turn on the main AC power supply to the
machine.
2. Connect the #21 work lead to or - on ter-
minal strip (T.S.2).
3. Set the Welding Mode switch to welding process
being used:
•
CC STICK (for SMAW and AAC)
•
CV SUBMERGED ARC (for SAW)
•
CV INNERSHIELD (for FCAW and GMAW)
4. Turn the POWER ON/OFF Toggle Switch to the
“ON” position
•
The white pilot light glows.
•
The fan starts.
5. Set OUTPUT CONTROL Potentiometer to desired
voltage or current.
6. Set the OUTPUT TERMINALS switch to either
“ON” ( output terminals energized) or “REMOTE”
(output terminals energized when #2 and #4
closed by remote device such as wire feeder)
7. Make the weld.
DC-600