Electromagnetic Compatibility (EMC) 

11/04 

This machine has been designed in accordance with all relevant directives and standards. However, it may still generate 
electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or 
other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand this 
section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.. 
 

This machine has been designed to operate in an industrial area. To operate in a domestic area it is 
necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The 
operator must install and operate this equipment as described in this manual. If any electromagnetic 
disturbances are detected the operator must put in place corrective actions to eliminate these disturbances 

with, if necessary, assistance from Lincoln Electric. 
 
Before installing the machine, the operator must check the work area for any devices that may malfunction because of 
electromagnetic disturbances. Consider the following. 

  Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the 

machine. 

  Radio and/or television transmitters and receivers. Computers or computer controlled equipment. 

  Safety and control equipment for industrial processes. Equipment for calibration and measurement. 

  Personal medical devices like pacemakers and hearing aids. 

  Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure 

that all equipment in the area is compatible. This may require additional protection measures. 

  The dimensions of the work area to consider will depend on the construction of the area and other activities that are 

taking place. 

 
Consider the following guidelines to reduce electromagnetic emissions from the machine. 

  Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take 

additional precautions such as filtering the input supply. 

  The output cables should be kept as short as possible and should be positioned together. If possible connect the 

work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting the 
work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment. 

  Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special 

applications. 

 WARNING 

The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public 
low-voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those 
locations, due to conducted as well as radiated disturbances. 

 

 

 WARNING 

This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to: 
 

CV 425

:   

S

sc

 

 9,5 MVA 

CV 510

:  

S

sc

 

 14,3 MVA 

 
at the interface point between the user’s supply and the public system. It is the responsibility of the installer or user of the 
equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected 
only to a supply with a short circuit power Ssc greater than or equal to data on the table above. 
 

Содержание CV 425

Страница 1: ...IM3033 09 2016 REV02 CV 425 510 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...0 380 440V K14081 2A CV 510 AIR 220 380 440V conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 1 2012 EN 60974 10 201...

Страница 3: ...to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Nu...

Страница 4: ...her surface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric an...

Страница 5: ...aper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry when possible and do not place...

Страница 6: ...ine on to allow the internal components to cool when the lamp turns off normal operation is possible 4 Low Inductance Negative Output Socket For connecting a work lead 5 High Inductance Negative Outpu...

Страница 7: ...the nearest Technical Service Center or Lincoln Electric Repairs and modifications performed by unauthorized service or personnel will cause that the manufacturer s warranty will become null and void...

Страница 8: ...area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction...

Страница 9: ...60 420 A 35 Vdc 100 325 A 30 3 Vdc CV 510 60 500 A 39 Vdc 100 385 A 33 3 Vdc OUTPUT RANGE Welding Current Range Open Circuit Voltage CV 425 10 A 420 A 10 39 Vdc CV 510 10 A 500 A 10 39 Vdc RECOMMENDED...

Страница 10: ...c Refer to the Spare Parts manual supplied with the machine Accessories K10347 PG xxM Source wire feeder cable gas Available in 5 10 15m K10347 PGW xxM Source wire feeder cable gas and water Available...

Отзывы: