Lincoln Electric CV 425 Скачать руководство пользователя страница 5

English 2 English 

 

WELDED MATERIALS CAN BURN:  Welding generates a large amount of heat. Hot surfaces and 
materials in work area can cause serious burns. Use gloves and pliers when touching or moving 
materials in the work area. 

 

CYLINDER MAY EXPLODE IF DAMAGED:  Use only compressed gas cylinders containing the correct 
shielding gas for the process used and properly operating regulators designed for the gas and pressure 
used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or 
transport gas cylinders with the protection cap removed. Do not allow the electrode, electrode holder, 
work clamp or any other electrically live part to touch a gas cylinder. Gas cylinders must be located 
away from areas where they may be subjected to physical damage or the welding process including 
sparks and heat sources. 

 

SAFETY MARK:  This equipment is suitable for supplying power for welding operations carried out in an 
environment with increased hazard of electric shock. 

 
The manufacturer reserves the right to make changes and/or improvements in design without upgrade at the same time 
the operator’s manual. 
 

Installation and Operator Instructions 

 
Read this entire section before installation or operation 
of the machine. 
 

Location and Environment 

This machine will operate in harsh environments. 
However, it is important that simple preventative 
measures are followed to assure long life and reliable 
operation: 

  Do not place or operate this machine on a surface 

with an incline greater than 15° from horizontal. 

  Do not use this machine for pipe thawing. 

  This machine must be located where there is free 

circulation of clean air without restrictions for air 
movement to and from the air vents. Do not cover 
the machine with paper, cloth or rags when switched 
on. 

  Dirt and dust that can be drawn into the machine 

should be kept to a minimum. 

  This machine has a protection rating of IP23. Keep it 

dry when possible and do not place it on wet ground 
or in puddles. 

  Locate the machine away from radio controlled 

machinery. Normal operation may adversely affect 
the operation of nearby radio controlled machinery, 
which may result in injury or equipment damage. 
Read the section on electromagnetic compatibility in 
this manual. 

  Do not operate in areas with an ambient temperature 

greater than 40°C. 

 

Duty cycle and Overheating 

The duty cycle of a welding machine is the percentage of 
time in a 10 minute cycle at which the welder can 
operate the machine at rated welding current. 
 
Example: 60% duty cycle 
 

 

Welding for 6 minutes. 

Break for 4 minutes. 

 

Excessive extension of the duty cycle will cause the 
thermal protection circuit to activate. 
 

 

 Minutes 

 

or 

decrease 

Duty Cycle 

 

 
The machine is protected from overheating by a 
temperature sensor. 
 

Input Supply Connection 

 

 WARNING 

Only a qualified electrician can connect the welding 
machine to the supply network. Installation the outlet 
plug to power lead and connecting the welding machine 
had to be made in accordance with the appropriate 
National Electrical Code and local regulations. 
 
Check the input voltage, phase, and frequency supplied 
to this machine before turning it on. Verify the 
connection of grounding wires from the machine to the 
input source. The allowable input voltages are 3x220V 
50/60Hz, 3x380V 50/60Hz and 3x440V 50/60Hz 
(3x440V: factory default). For more information about 
input supply refer to the technical specification section of 
this manual and to the rating plate of the machine. 
 
If it is necessary to change the input voltage: 

  The input cable must be disconnected from the 

mains supply and the machine switched OFF. 

  Remove the left side panel. 

  Reconnect X6 according to the diagram below: 

 

220V

380V

440V

X6

X6

X6

 

Figure 1. 

 

Содержание CV 425

Страница 1: ...IM3033 09 2016 REV02 CV 425 510 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...0 380 440V K14081 2A CV 510 AIR 220 380 440V conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 1 2012 EN 60974 10 201...

Страница 3: ...to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Nu...

Страница 4: ...her surface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric an...

Страница 5: ...aper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry when possible and do not place...

Страница 6: ...ine on to allow the internal components to cool when the lamp turns off normal operation is possible 4 Low Inductance Negative Output Socket For connecting a work lead 5 High Inductance Negative Outpu...

Страница 7: ...the nearest Technical Service Center or Lincoln Electric Repairs and modifications performed by unauthorized service or personnel will cause that the manufacturer s warranty will become null and void...

Страница 8: ...area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction...

Страница 9: ...60 420 A 35 Vdc 100 325 A 30 3 Vdc CV 510 60 500 A 39 Vdc 100 385 A 33 3 Vdc OUTPUT RANGE Welding Current Range Open Circuit Voltage CV 425 10 A 420 A 10 39 Vdc CV 510 10 A 500 A 10 39 Vdc RECOMMENDED...

Страница 10: ...c Refer to the Spare Parts manual supplied with the machine Accessories K10347 PG xxM Source wire feeder cable gas Available in 5 10 15m K10347 PGW xxM Source wire feeder cable gas and water Available...

Отзывы: