background image

English 18 English 

WEEE 

07/06 

English

 

 

Do not dispose of electrical equipment together with normal waste! 
In observance of European Directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) 
and its implementation in accordance with national law, electrical equipment that has reached the end of its 
life must be collected separately and returned to an environmentally compatible recycling facility.  As the 
owner of the equipment, you should get information on approved collection systems from our local 
representative. 
By applying this European Directive you will protect the environment and human health! 

 

Spare Parts 

12/05 

Part List reading instructions 

  Do not use this part list for a machine if its code number is not listed.  Contact the Lincoln Electric Service 

Department for any code number not listed. 

  Use the illustration of assembly page and the table below to determine where the part is located for your particular 

code machine. 

  Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate 

a change in this printing). 

 
First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that 
contains a picture-descriptive part number cross-reference. 
 

REACh 

11/19 

Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006 – REACh. 

Some parts inside this product contain: 
Bisphenol A, BPA, 

 

EC 201-245-8, CAS 80-05-7 

Cadmium, 

 

 

EC 231-152-8, CAS 7440-43-9 

Lead, 

 

 

 

EC 231-100-4, CAS 7439-92-1 

Phenol, 4-nonyl-, branched, 

EC 284-325-5, CAS 84852-15-3 

in more than 0,1% w/w in homogeneous material. These substances are included in the “Candidate List of Substances 
of Very High Concern for Authorisation” of REACh. 
Your particular product may contain one or more of the listed substances. 
Instructions for safe use: 

  use according to Manufacturer instructions, wash hands after use; 

  keep out of reach of children, do not put in mouth, 

  dispose in accordance with local regulations. 

 

Authorized Service Shops Location 

01/19 

  The purchaser must contact Lincoln Electric or Authorized Service Facility about any defect claimed under warranty 

period. 

  Contact your local Sales Representative for assistance in locating the nearest Authorized Service Facility. 

 

Electrical Schematic 

 
Refer to the "Spare Part" manual supplied with the machine. 
 

Содержание Cool Arc 26

Страница 1: ...IM3101 12 2019 REV04 COOL ARC 26 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland ...

Страница 2: ...the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased INDEX Technical Specifications 1 Electromagnetic Compatibility EMC 2 Safety 3 Introduction 5 Unpacking 5 Installation on Power Source 5 Installation and Operator Instructions 8 WEEE 18 Spare Parts 18 REACh 18 Authorized ...

Страница 3: ... 26 Recommended coolant FREEZCOOL W000010167 COOL ARC 26 Do not use Pre packaged welding industry coolants These coolants may contain oil based substances which attack the plastic components of the cooler Once added to the cooler these substances are impossible to purge from the water lines and heat exchanger Automotive anti freeze These coolants will damage the pump and block of the heat exchange...

Страница 4: ...f disturbances occur if may be necessary to take additional precautions such as filtering the input supply The output cables should be kept as short as possible and should be positioned together If possible connect the work piece to ground in order to reduce the electromagnetic emissions The operator must check that connecting the work piece to ground does not cause problems or unsafe operating co...

Страница 5: ...tor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It...

Страница 6: ...linders with the protection cap removed Do not allow the electrode electrode holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process including sparks and heat sources HOT COOLANT CAN BURN SKIN Always be sure coolant is NOT HOT before servicing the cooler The man...

Страница 7: ...ting sharp objects through the carton liner which may puncture the plastic reservoir Save the manual instruction and service directory supplied with the COOL ARC 26 for parts orders and future maintenance service Installation on Power Source The COOL ARC 26 need to be mounted directly to the chassis of MIG welding power source that lists the COOL ARC 26 as an approved accessory WARNING Only a qual...

Страница 8: ...English 6 English Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 ...

Страница 9: ...English 7 English Figure 7 Figure 8 Figure 9 ...

Страница 10: ...gnetic compatibility in this manual Do not operate in areas with an ambient temperature higher than 40 C The ambient air temperature influences the parameters of cooling If the ambient temperature is higher the cooling system will be less effective WARNING Avoid placing the cooler near areas of extreme heat RECOMMENDED POWER SOURCE The COOL ARC 26 is designed for use with water cooled torches The ...

Страница 11: ... Cooler Figure 12 WARNING Avoid kinking or putting sharp bends in any water lines WARNING Never operate the cooler with case off Modes of operation COOL ARC 26 can be operate using two interfaces The standard version U0 Figure 14 uses two LED displays While the advance version U7 Figure 13 uses a 7 display The method of operating both interfaces is describe in the operating instructions for the de...

Страница 12: ...English 10 English Advanced User Interface U7 Cooler Configuration Settings Auto Off On Figure 13 ...

Страница 13: ...English 11 English Standard User Interface U0 Figure 14 ...

Страница 14: ...ly starts the filling procedure Figure 15 or 24 Remove the reservoir cap to prevent generating a partial vacuum Fill the coolant reservoir to the maximum level 4 liters Figure 16 or 25 Connect the short black hose with quick water connectors BYPASS included with the equipment to blue outlet socket on front of the power source Observe the coolant circuit wait till the coolant starts leak from the B...

Страница 15: ...English 13 English Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Standard User Interface U0 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 ...

Страница 16: ...e an image will be shown on the screen as on Figure 35 or 36 Figure 35 Figure 36 If during the second attempt filling procedure failed Figure 37 or 38 please turn the power source off and check cooling system hoses conditions bent or damaged coolant level WAIT 1 2 3 4 5 6 7 8 Procedure failed Figure 37 Figure 38 After review turn on the power source Machine will automatically start with filling pr...

Страница 17: ...by unauthorized service or personnel will cause the manufacturer s warranty to become null and void Any noticeable damage should be reported immediately and repaired ROUTINE MAINTENANCE Check the condition of water cooler hoses and connections of the power lead Check the welding torch gun condition replace it if necessary Check condition and operation of the cooling fan Keep its airflow slots clea...

Страница 18: ...rs may ask Lincoln Electric for advice or information about their use of our products We respond to our customers based on the best information in our possession at that time Lincoln Electric is not in a position to warrant or guarantee such advice and assumes no liability with respect to such information or advice We expressly disclaim any warranty of any kind including any warranty of fitness fo...

Страница 19: ... lead or order new lead set Clear blockage in hose Avoid kinking or putting sharp bends in water lines Repair leak Fill reservoir Replace fuse Internal water leak Hose clamp loose on one of internal hoses Internal hose punctured Heat exchanger leaking Tighten or replace hose clamp Replace punctured hose with new hose Replace heat exchanger Leak at inlet outlet connector block Hose clamp loose Tigh...

Страница 20: ...ange in this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7...

Страница 21: ...English 19 English Accessories W000010167 FREEZCOOL coolant T 5041 003 1R RED HOSE 150 mm T 5041 004 1R BLUE HOSE 115 mm D 2218 150 1R BYPASS HOSE 200 mm ...

Отзывы: