TO USE THE CLASSIC III OR CLASSIC
IIID FOR DC WIRE FEED WELDING
(CONSTANT VOLTAGE WITH WIRE FEED
MODULE):
1.
Connect the LN-25, LN-23P, or LN-7 Wire Feeder.
Follow the installation instructions provided with
the wire feeder.
2.
Set the machine for CV operation.
3.
Start the engine. See
Engine Operation in this
section of the manual.
4.
Set the Idler Switch to "AUTO."
5.
Set the CURRENT RANGE SELECTOR to a set-
ting appropriate for your wire size and wire feed
speed. See Table B.1 for recommended settings.
6.
Set the VOLTAGE ADJUSTMENT to the setting
that gives the best arc characteristics for the range
selected.
7.
Pull the gun trigger and begin welding.
OPERATION
B-12
B-12
Classic III and IIID
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
TABLE B.1
RANGE SETTINGS FOR WIRE SIZE/SPEED
Diameter (inches)
Wire Speed Range
Appropriate Current Range
(inches/minute)
.035
80-110
80 to 130 Amps
.045
70-130
120 to 190 Amps
.068
40-90
150 to 240 Amps