A-21
OPERATION
APEX
®
3 SERIES TIG PENDANT MANUAL
Static Screen Items
There are many items common throughout the Idle,
Weld and Test screens. These items give helpful
information to the user throughout the setup and
welding process.
1. Arc Time -
Indicates the amount of time spent
welding.
2. Heat Input -
Displays the amount of heat input for
current weld in kilojoules/cm.
3. Sector -
Displays the current sector in the weld
program, if applicable
4. Program Name -
Displays the currently loaded weld
program and program pass
Note: Program Name changes to Italics when
program parameters have changed
5. Oscillation Location -
Displays the relative location
of the oscillation axis.
6. Torch Height -
Displays the relative location of the
height axis.
The screen shot above –
FIGURE 9 - Static Items
– illustrates the icons that appear o the weld screen.
These icons are for information only and are not select-
able variables.
Test Screen
Similar to the Weld screen, the Test Screen will show
voltage and amperage feedback, but the feedback
values will be zero – see
FIGURE 10 - Test Screen
Options.
Pressing the menu buttons will move the user
through the Menu Option Variables as shown in the
Idle Screen section.
Auto Height is disabled while testing. The ability to
feed wire is typically turned of while testing.
Test Screen Buttons
The Test Screen buttons work similar to the weld
screen buttons –
see FIGURE 11 - All Test Screens
.
FIGURE 10 - Test Screen Options
FIGURE 11 - All Test Screens
FIGURE 9 - Static Items
Содержание APEX 3 Series