E-4
TROUBLESHOOTING
FRONTIER
®
400X
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Engine goes to low idle but does
not stay at low idle.
No welding output or auxiliary
output.
Welder has some/ no output and no
control. Auxiliary output OK
No welding output. Auxiliary output
OK.
No auxiliary power.
1. Faulty Idle Relay.
1. Broken lead in rotor circuit.
3. Faulty rotor.
1. Faulty remote kit.
2. Faulty output control
potentiometer.
3. Faulty output control wiring.
1. Output terminals may be set to
Remote in the settings.
1. Open breakers may need to be
reset.
2. GFCI tripped.
3. Faulty breaker(s), receptacle, or
GFCI.
4. Faulty auxiliary circuit wiring.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
FUNCTION PROBLEMS
Observe all Safety Guidelines detailed throughout this manual
2. Intermittent Auxiliary load
3. Remote trigger input is present.