Page 6
Maxmig 330R
IMA 566BLA
1.
INSTALLATION
Machine Installation
1.1 Location
Place the welder where clean cooling air can freely
circulate in through the front louvers and out through the
rear louvers. Dirt, dust or any foreign material that can be
drawn into the welder should be kept at a minimum. Failure
to observe these precautions can result in excessive
operating temperatures and nuisance thermostat trips.
1.2 Connection to Mains Supply
Before connecting the machine to the mains supply check
that the voltage and current capacity correspond to the
machine voltage and rated input current. Use a fuse or C/B
per AS3000 or local wiring rules.
The machine is supplied with an input lead fitted. Have a
qualified electrician fit a suitable input plug.
1.3 Shielding Gas Supply (For the Gas Metal
Arc Welding Process)
Refer “Safety in welding and cutting” - ANSI Standard Z49-
1 and WTIA Technical Note 7, available from the Welding
Technology Institute of Australia.
Obtain cylinder of appropriate type shielding gas for the
process being used.
• Turn the input power o f f a t
t h e d i s c o n n e c t s w i t c h
before in s t a l l i n g or servicing
this machine.
• Do not touch e l e c t r i c a l l y
“ h o t ” parts such as o u t p u t
terminals or internal wiring.
• Connect grounding screw ( )
t o a g o o d e a r t h g r o u n d .
• Do not operate with c o v e r s
removed.
• Turn power switch “off” before
connecting or disconnecting
c a b l e s o r o t h e r e q u i p m e n t .
PRODUCT DESCRIPTION
The Maxmig 330R offers a remote wire feeder and a separate constant voltage DC arc welding machine. They combine a solid state
controlled power source with similarly controlled wire feeding equipment.
Excellent arc characteristics are provided for both gas shielded and self shielded welding within its current range.
Standard features include output volt & amp meters, a spot timer, gas purge facilities, a dual position 2 or 4 step trigger interlock, a Maxmig
360 MIG gun, a regulator/flowmeter and gas hose, ground cable assembly 5m, a 3m long input lead and an undercarriage on which a gas
cylinder can be mounted.
Model
Maxmig 330R
Part No.
05-4330 (Remote)
Maximum Open Circuit Voltage
45V
Output Current Range
up to 400A
Duty Cycle
30%
60%
100%
Rated Output
320A/30V
240A/26V
190A/23.5V
Rated Input
415V 3ph 50Hz 13.5 amps
Wire Speed Range
1-20 m/min
Weight (complete with u/c)
130 kg
H x W x L (mm) Over lift
bail, cylinder tray & wheels
1129 x 525 x 885mm
Operating Temperature
-20˚C to 40˚C
WARNING
HIGH
VOLTAGE
can kill
CYLINDER may explode if
damaged
Specifications
Only qualified personnel should install this equipment.
Never connect the green/yellow conductor to any of the
three active supply lines from the mains. This conductor is
to earth the machine as required by Electrical Regulations.
Once the above has been followed the machine can be
plugged into the mains outlet.
CAUTION