Lincoln Electric 05-4330 Скачать руководство пользователя страница 23

IMA 566BLA

Maxmig 330R

Page 23

# Indicates a change this printing.

* Items not illustrated.

ITEM

DESCRIPTION

PART NO.

QTY.

1

2

3

4

5

6

7

8

9

1

Base Front and Rear

AG1410

1

x

2

Vibro Isolator

AS4404-3

4

1

3

Bulkhead

AL2648

1

x

4

Motor control PCB

AS4212-4SP

1

x

5

Gas Solenoid 42V

AM3399-1

Brass Male Straight Tailpiece

AT3730-3

1

x

Brass Male Elbow Tailpiece

AT3070-9

6

Earth Tag

AT3166

1

x

7

Red Microswitch

AT3561-1

2

x

8

Toggle Switch Spot

T13562

1

x

9*

Lead Harness

AL2652

1

x

10

Potentiometer insulation

T12T92-1

2

x

11

Nameplate

AM3572-1

1

x

Fastener Button (black)

T14659-1

4

x

12

Wire Feed Pot

AS4212-2

1

x

12a

Rheostat Knob

T10491

1

x

13

Spot Timer Pot

AS4212-1

1

x

13a

Rheostat Knob

T10491D

1

x

14

Bulkhead Support

AM3577

1

x

15

Spool Post

AM3387SP

1

x

Spacer Washer

AS4482

1

x

16

Gun Adaptor Reworked

AS4456-1

1

x

17

Drive Plate Assembly

AM3391-8

1

x

18

Insulating Washer

AT2882

2

x

19

Plastic Washer/Tube

AM3391-1S

2

x

20

Wire Drive Mounting Bracket

AM3390-2

1

x

21

Drive Motor and Gearbox

AM3185

1

x

22*

Insulating Splice

T12068-1

1

x

23*

Cable Tie

10

x

24

Cable Assembly

AL2656-1

1

x

25

Magnetic Catch

AS4554

2

x

26

Door and Roof Assembly

AG1411

1

x

27

Rubber Buffer

AS4404-1

1

x

28

Handle

M15446

1

x

29

Side Panel

AL2650

1

x

30

Motor and Gear Box

AM3185

1

x

Use only the parts marked “X” in the column under the
heading number called for in the model index page.

AP-93-C1

Operative:

4.7.03

Supersedes:

28.10.98

Recommended Spare Parts are highlighted in bold
Nut, bolt and washer sizes are given so they may be procured locally.

Содержание 05-4330

Страница 1: ...r your overall safety can be increased by proper installation and thoughtful operation on your part Read and observe the general safety precautions on page 2 and follow specific installation and opera...

Страница 2: ...understand the manufacturer s instructions for this equipment and the consumables to be used including the material safety data sheet MSDS and follow your employer s safety practices e Also see Item 7...

Страница 3: ...guards to perform required maintenance Remove guards only when necessary and replace them when the maintenance requiring their removal is complete Always use the greatest care when working near moving...

Страница 4: ...ng can interfere with a pacemakers function Generally the interference does not permanently damage the pacemaker Once the wearer leaves the arc welding environment or stops welding the pacemaker retur...

Страница 5: ...ing or other activities are to be carried out The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place The surrounding...

Страница 6: ...ith covers removed Turn power switch off before connecting or disconnecting cables or other equipment PRODUCT DESCRIPTION The Maxmig 330R offers a remote wire feeder and a separate constant voltage DC...

Страница 7: ...onnector and then join the connectors and tighten the hand nut on the gun cable connector Note If a gun and cable other than the supplied gun is to be used it must conform to standard European supplie...

Страница 8: ...approximately 1 to 20 meters min 40 to 790 inches min Operation of the gun trigger switches the wire feed motor on and off depending upon the mode setting The wire feed motor is dynamically braked to...

Страница 9: ...tegrated model the spool turns anti clockwise when looking at the spool For the remote unit the spool turns clockwise when looking at the spool Carefully release the end of the wire from the spool ens...

Страница 10: ...e cable over its entire length and again blow out the cable Repeat this procedure until no further dirt comes out Gun Tips and Nozzles The gun tip should be replaced when worn Replace with the correct...

Страница 11: ...visually inspect the PC board in question for any visible damage to any of its components and conductors on the back of the board 1 If there is no visible damage to the PC board install a new one and...

Страница 12: ...spect gun cable and replace if necessary Remove wire from gun and cable feed in new wire Note any obstructions in gun and cable Replace gun and cable if necessary See Wire Drive Roll Section in this m...

Страница 13: ...h button is depressed If this voltage is over 10V DC replace the wire feed motor If no voltage is registered replace the wire drive PCB Refer PCB replacement procedure at end of Trouble Shooting Guide...

Страница 14: ...Page 14 Maxmig 330R IMA 566BLA NOTES...

Страница 15: ...table below indicate which column to use in each parts list for each individual code number Sub Assembly Item No 1 2 3 4 5 Sub Assembly Page Name Machine Part List No AP 70 C AP 70 D AP 103 AP 70 W IM...

Страница 16: ...Page 16 Maxmig 330R IMA 566BLA General Assembly Maxmig 330R AP 70 C Operative 4 7 03 Supersedes 28 10 98 Ref AG1347 5...

Страница 17: ...1 x 16 Contactor AM3423 1 X 17 Auxiliary Transformer PT0050 1 x 18 Swivel Castor 4 AS4070 2 x 19 Front Panel AL2532A1 1 x 20 Main Transformer Assy AL2494 1 x 21 Output Stud AM2454 1 2 x 22 Rotary Swit...

Страница 18: ...Page 18 Maxmig 330R IMA 566BLA Front Panel Assembly Maxmig 330R AP 70 D Operative 4 7 03 Supersedes 28 10 98 8 9 10 11 Ref AL2655 A...

Страница 19: ...itch 8 position AM3388 3 1 x 5 Rotary Switch 4 position AM3388 4 1 x 6 Moulded Output Stud AM2464 1 2 x 7 Flange Nut T3960 2 x 8 Shunt 400A S6602 22 1 x 9 Pilot Light AT3384 1 1 x 10 Indicator Over Te...

Страница 20: ...Page 20 Maxmig 330R IMA 566BLA AM3578 4 for Code No 1546 Wiring Diagram Maxmig 330R AP 70 W Operative 4 7 03 Supersedes 28 10 98...

Страница 21: ...epartment for any code numbers not listed Numbers in the table below indicate which column to use in each parts list for each individual code number Sub Assembly Item No 1 2 3 4 5 Sub Assembly Page Na...

Страница 22: ...Page 22 Maxmig 330R IMA 566BLA General Assembly Maxidrive 2R AP 93 C Operative 4 7 03 Supersedes 28 10 98 Ref AG1412 for Code 1547...

Страница 23: ...x 13a Rheostat Knob T10491D 1 x 14 Bulkhead Support AM3577 1 x 15 Spool Post AM3387SP 1 x Spacer Washer AS4482 1 x 16 Gun Adaptor Reworked AS4456 1 1 x 17 Drive Plate Assembly AM3391 8 1 x 18 Insulati...

Страница 24: ...H Circlip Idle Roll AM3391 1H 1 x N Tensioner AM3391 1N 1 x P Circlip Idle Roll Arm Shaft AM 3391 1P 1 x R Drive Roll Retaining Screw AM3391 1R 1 x V Incoming Guide Tube AM3391 1V 1 x 3C Idle Roll Ar...

Страница 25: ...IMA 566BLA Maxmig 330R Page 25 AM3574 for Code No 1547 Wiring Diagram Maxidrive 2R AP93 W Operative 28 10 98 Supersedes NEW...

Страница 26: ...Page 26 Maxmig 330R IMA 566BLA Maxmig 360 TBi Welding Torch AP 103 F Operative 4 7 03 Supersedes NEW...

Страница 27: ...male 375P000004 160 Spring support small 600P102099 162 Adapter support 701P001045 163 Screw M4 x 6 100P008401 164 Adapter Nut 701P001013 170 ESG connector complete 701P001002 174 O Ring 365P100040 1...

Страница 28: ...ods and service requirements CONDITION OF WARRANTY TO OBTAIN WARRANTY COVERAGE The purchaser must contact Lincoln or Lincoln s Authorised Service Facility about any defect claimed under Lincoln s warr...

Отзывы: