background image

REG.N.4796

UNI EN ISO 9001:2008 

IT

EN

RIVELATORE DA INTERNO IN DOPPIA 

TECNOLOGIA VIA RADIO

Manuale di installazione, uso e manutenzione

Installation, operation and maintenance manual

DUAL TECHNOLOGY WIRELESS DETECTOR FOR 

INDOOR USE

ART. / ITEM: 

4058GR868DT

4097GR868DT/T

GR868DT

MADE IN ITALY

Содержание GR868DT

Страница 1: ...LATORE DA INTERNO IN DOPPIA TECNOLOGIA VIA RADIO Manuale di installazione uso e manutenzione Installation operation and maintenance manual DUAL TECHNOLOGY WIRELESS DETECTOR FOR INDOOR USE ART ITEM 4058GR868DT 4097GR868DT T GR868DT MADE IN ITALY ...

Страница 2: ...rtata Radio aria libera 100 m Portata di rilevazione 12 m Copertura orizzontale 90 6 Temperatura di eserzio 5 40 C Peso solo rilevatore 110 g Translation of the original instructions original instructions in Italian The information in this manual has been issued with care but LINCE ITALIA S p A will not be responsible for any errors or omissions LINCE ITALIA S p A reserves the right to improve or ...

Страница 3: ...ttronica F Microinterruttore antiapertura G Trimmer regolazione sensibilità della microonda H Viti parker fissaggio scheda elettronica I Frontale con lente di Fresnel 3 NOTICES It is good practice to carefully assess the area to be protected before installing the detector avoiding any blind spots in the area surveyed furniture shelves etc Prevent moving objects from invading the area to be protect...

Страница 4: ...ccare il movimento dello snodo serrando le due viti C Rimontare la scheda elettronica E fissandola con le viti parker I Inserire la batteria vedi capitolo relativo alla memorizzazione 9 inibizone 5 INSTALLATION For wall mounting the recommended height is between 2 1 m and 2 3 m The detector bracket means that it can be installed on the ceiling and or at heights above those recommended in these cas...

Страница 5: ...f test successivamente alla prima attivazione del rilevatore togliere la pila per qualche secondo e re inserirla 4 é necessario attivare la supervisione sulla ricevente facendo riferimento al relativo manuale 6 STORAGE For the storage procedure place the battery when required by manual of the uesed receiver 7 TEST FUNCTION This function was implemented to facilitate configuration of the detector T...

Страница 6: ...tore quindi occorre attendere almeno tre minuti senza alcuna rilevazione 10 GRAFICO DI COPERTURA Fig 3 VISTA IN PIANTA PLAN VIEW VISTA LATERALE SIDE VIEW 4058GR868DT 4097GR868DT T 9 STAND BY MODE In normal operating mode LEDs off the detector automatically switches to STAND BY to save on battery this means that if the area is in use the sensor will remain in stand by mode until there is at least 3...

Страница 7: ...ENZIONE Non disperdere nell ambiente i componenti ed ogni altro materiale del prodotto Rivolgersi a consorzi abilitati allo smaltimento ed al riciclag gio dei materiali 11 MAINTENANCE AND PERIODIC CHECKS 11 1 CLEANING THE EXTERNAL PART OF THE DE TECTOR Keep the lens clean to guarantee proper operation of the detector A lens which is not perfectly clean may cause detection pro blems and or problems...

Страница 8: ...001530 00321AD LINCE ITALIA S p A Via Variante di Cancelliera snc 00040 ARICCIA Roma Tel 39 06 9301801 Fax 39 06 930180232 info lince net www lince net ...

Отзывы: