IS 769      ECN 4688 

Page 9 of 13 

 

 

 
Drain and flush all de-scaling agent from the tank completely as follows: 
 
Unscrew the drain plug (beneath the grommet 

– Fig 1 G) using a 24mm spanner to 

hold the plug and a 21mm socket on a ratchet (Fig 3) to remove it from the bottom 
of the tank.  Drain all the water out. 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

Fig 3 

 
Flush out the tank with clean water. 
 
When empty, replace the drain plug and replace the grommet. 
 
Replace the tank lid, ensuring the gasket seals the top of the tank correctly. 
 
Refit the outer cover and turn the boiler on. 
 
 
 
 

Содержание WMB5F/B

Страница 1: ...oiler WMB5F B WMB5F W WMB7F B WMB7F W Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number _________...

Страница 2: ...ormation and Guarantee 12 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and n...

Страница 3: ...lean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning This appliance is not suitable for outdo...

Страница 4: ...unting holes Drill the holes and insert suitable wall plugs Remove the glass front outer body of the boiler by firstly removing the tap circlip and nut Remove the screw holding the lower centre trim a...

Страница 5: ...back panel and connected to a suitable drain Ambient temp Deg C Water inlet pressure Bar Water inlet pressure kPa 5 to 30 1 to 8 100 to 800 Turn on the water supply and check for leaks before refitti...

Страница 6: ...Adjustment water temperature screen backlight and contrast Fig 1 Consult Fig 1 Turn power off at the mains for 5 seconds and then back on again When the Filterflow screen is displayed press and hold...

Страница 7: ...If the appliance is to be left unused for any length of time turn the element off by pressing the power button Filter replacement The filter display shows the estimated life left in the filter cartri...

Страница 8: ...at the end of the working day gives the de scaling agent several hours to work Lincat recommend our own de scaling agent MS19 available from our Spares department Wear protective clothing Isolate the...

Страница 9: ...g a 24mm spanner to hold the plug and a 21mm socket on a ratchet Fig 3 to remove it from the bottom of the tank Drain all the water out Fig 3 Flush out the tank with clean water When empty replace the...

Страница 10: ...all service for advice Message displayed Possible causes Corrective action Scale on level sensors Boiler overfilling Descale Check water inlet valve Water turned off Inlet hose kinked or blocked Water...

Страница 11: ...LE47 Level sensor insulator LE48 Upper level sensor LE51 Lower level sensor PR73 Circuit board SI01 Sensor isolator SL20 Tap nut SL21 Tap circlip SL34 Tap body SO24 Solenoid SW88 Momentary switch TE4...

Страница 12: ...ot diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bu...

Страница 13: ...IS 769 ECN 4688 Page 13 of 13 Wall mount position 330 290 17 5 17 5 130 410 FIXING CRS FIXING CRS 11 5 FIXING CRS BODY...

Отзывы: