SECTION 4 – COMPONENT REPLACEMENT 
 
4.1. LIGHT REPLACEMENT 

 
1.

 

Disconnect the mains supply. 

2.

 

Pull the lamp away from the hood by gripping the edge of the bezel. 

3.

 

When the spring becomes exposed, push it back against the lamp body to allow it to come through the 
hole in the hood. 

4.

 

Unclip the terminal block from the failed lamp and clip the new one in place (the one supplied with 
the replacement is surplus to requirements). 

5.

 

Twist the bezel to release it and re-fit to the new lamp. 

6.

 

Fold up the springs against the body of the lamp and slot back through the hole in the hood. 

 
4.2. MOTOR REPLACEMENT 

 

1.

 

Isolate the power supply at the fan speed controller or the distribution board. 

2.

 

Remove the baffle filters necessary to access the motor. This is achieved by sliding the filter up a 
short distance (no more than 20mm) and swinging out from the base. 

3.

 

Either one or two of the filter infills will need to be removed. The necessary infills are screwed in (the 
remainder are riveted and not intended to be removed). If the infill appears down the centre of the 
motor, check the upper and lower edges for the fixing screws and remove with a T15 Torx driver. If 
two infills overlap the motor at each end, these will be removable by the same procedure. 

4.

 

Disconnect the motor supply connection (see page 5). 

5.

 

Mark each motor support bracket screw mounting hole, for future reference when re-mounting the 
motor. 

6.

 

Remove the two self-tapping screws holding the motor to each support bracket and carefully 
withdraw the motor from the SmartVent. 

7.

 

Fit the motor by reversal of the above procedure ensuring the motor is relocated correctly inside the 
exhaust flange. 

 

4.3. REPLACEMENT COMPONENT LIST 

 

                      

LA363
LED Downlighter

FI40
Baffle Filter

FA126
Fan Motor

Note mounting holes

PART 

NUMBER 

DESCRIPTION 

FA126 

0

·

12kW Centrifugal Fan 

FI40 

Baffle Filter 

LA363 

7W LED Downlight Lamp 

LA364 

Replacement Bezel for Lamp 

Содержание SV1212

Страница 1: ...IS554 ECN3869 User and Installation Instructions SmartVent Range of Extraction Canopies SV1212 SV1216 SV1220 SV1224 LH LV CH CV RH RV...

Страница 2: ...S6173 2009 WARNING Competent personnel familiar with the assessment of hazards and risks associated with industrial ventilation equipment such as fans and air handling units should install this produc...

Страница 3: ...Filters 2m to finished floor Baffle Filters Lighting L LEFT R RIGHT C CENTRE H HORIZONTAL V VERTICAL 200 Note the exhaust may exit at the left centre or right and either horizontally or vertically de...

Страница 4: ...n structure 280 280 520 130 500 500 1100 125 280 130 920 280 500 125 700 500 SV1212 SV1224 SV1216 SV1220 2 3 2 MOUNTING LEFT AND RIGHT MOUNTED FANS If installing a hood with a left or right hand locat...

Страница 5: ...ises lighting circuit will be required by simple connection into one of the end downlighting LED lamps Note the L N and E connections are clearly marked Detachable terminal block from LA363 downlighte...

Страница 6: ...speed controller and energise the gas interlock You are now ready to operate Ensure the installer has advised you the lowest setting to safely operate the SmartVent without nuisance activation of the...

Страница 7: ...the base 3 Either one or two of the filter infills will need to be removed The necessary infills are screwed in the remainder are riveted and not intended to be removed If the infill appears down the...

Страница 8: ...The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions...

Отзывы: