Lincat OG8801 Скачать руководство пользователя страница 6

IS 582   ECN 3851 

Page 6 of 17 

 

 

The appliance is type ‘A’.  Rooms must be ventilated in compliance with existing 
technical regulations.  The airflow must not be less than 2 cubic metres per hour per 
kW of installed capacity. 
 
If the appliance must be fitted near walls, partitions kitchen furniture etc we 
recommend they are made from non-inflammable material, otherwise they should be 
covered with a suitable heat-resistant material.  Full attention must be paid to fire 
prevention regulations 
 
If the supply pressure exceeds 37mbar for 3rd family gases then an external 
regulator must be fitted at the appliance inlet 
 
The water inlet must be between 50 and 300 kPa.  The hose set supplied with the 
appliance must be used– the old hose set is not to be re-used. 
 
If this appliance is fitted with castors, use caution at all times when manipulating or 
moving, and lock castors when appliance is in position. Drain the appliance BEFORE 
moving it. 
 

Connecting to a gas supply 

Installation and connection to the gas supply must only be carried out by a technician 
authorised by your local gas supplier.  Before connection, ensure that the appliance 
is suitable for the type of gas supplied.  Ensure the gas supply is provided with an 
isolating cock for emergency shutdown.   Ensure that the supply hose shall comply 
with the national requirements in force and shall be periodically examined and 
replaced as necessary.  These appliances are to be installed with sufficient 
ventilation to prevent the occurrence of unacceptable concentrations of substances 
harmful to health in the room in which they are installed. 
Appliances fitted on castors must be suitably restrained to prevent strain on supply 
hoses 
 

WARNING : Black domestic hoses are not suitable for this appliance. 

 
Once installation is complete, ensure all joints are leak free. 
 
Earth and equipotential connection 
The appliance must be connected to an equipotential system – the terminal is 
situated near the entry point of the electrical supply cable and is marked by the 
symbol  
The appliance must be earthed.  Connect the earth cable to the terminal near the 
terminal block marked by the symbol  
 

START THE APPLIANCE FOLLOWING THE OPERATING INSTRUCTIONS 

 

Inspection of the gas supply 
Check ignition and correct lighting of burners, pilot flame operation and check for any 
gas leaks.  Check the efficiency of the waste gas removal system and the operation 
of aeration systems. If necessary, consult the section ‘Potential troubleshooting and 
solutions’. 

Содержание OG8801

Страница 1: ...0 Gas Heated Tilting Bratt Pan OG8801 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Страница 2: ...e Information and Guarantee 16 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your ...

Страница 3: ... supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person Ensure that the plug socket is accessible at all times Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model OG8801 N OG8801 P Height mm 900 900 Width mm 900 900 Depth mm 800 800 Height Lid Up mm 1600 1600 Weight kg 184 184 Nominal Gas gross kW 24 5 23 0...

Страница 4: ...to health in the room of installation There must be a minimum free area of 4 5cm2 per kW of total heat input Allow for a sufficient flow of fresh air for complete gas combustion Do not connect directly to any flue ducting or mechanical extraction system The gas supply hose or tubing shall comply with national requirements in force and shall be periodically examined and replaced as necessary An equ...

Страница 5: ... poles must be incorporated into the fixed wiring of this appliance The fixed wiring insulation must be protected by insulated sleeving having a temperature rating of H 07 RN F Supply cords shall be oil resistant sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 The appliance must be installed in a well ventilated place and at...

Страница 6: ...ble for the type of gas supplied Ensure the gas supply is provided with an isolating cock for emergency shutdown Ensure that the supply hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful t...

Страница 7: ...ion of the rated thermal output When the installation and adjustment operations are complete or after performing maintenance please verify the condition of the appliance and check the rated thermal output of the appliance The rated thermal output is indicated in the table Technical Data Inspection of gas connection pressure To measure the gas connection pressure use a manometer with a minimum desi...

Страница 8: ... hand wheel for tilting the pan and a button for filling with water The valve knob a sets the temperature of the tank and the gas burner ignites automatically when switched to the on position The simmer rocker switch b allows for a gentle heat once the food product has been brought to temperature This is ideal if the food is prone to burning in particular milk or cream based products Small flames ...

Страница 9: ...g on the bratt pan Press and turn the valve control knob to the desired setting Ensure simmer setting switch is pressed in the up position towards the larger three flames engraved on the facia just above the switch Switching on the simmer mode The bratt pan has a simmer setting to be used with sensitive products that require a gentler heat i e milk or cream based recipes Switch the appliance on as...

Страница 10: ... accessed by removing the front control panel The lid springs should be done at the same time These are accessed by removing the cover located at each end by screws Do not use a water jet or steam cleaner and do not immerse this appliance Always disconnect the appliance from the mains supply before cleaning or maintenance Steel parts can be cleaned using a cloth with water and mild detergent aggre...

Страница 11: ...e controller screws Replace flame controller Control thermostat Remove control knobs and facia panel Unscrew the fixing screws and disconnect the wiring Remove the thermostat from the switch Remove rear thermostat bulb cover plate Remove the thermostat bulb from the bracket Safety thermostat Remove facia panel Unscrew the fixing screws and disconnect the wiring Remove rear thermostat bulb cover pl...

Страница 12: ...connect the electrical connections of the device Replace the component Tank Remove right hand side panel and remove and replace components as necessary Water solenoid Remove the front lower control panel Remove and replace the component This appliance cannot be converted by the user CONVERSION ...

Страница 13: ...ifficult uneven or unsuccessful lighting of burners Insufficient gas pressure Blocked pipe work or injector Defective gas valve Intervention of safety thermostat Thermostat defective Tank lifting micro switch defective Burners going out during use Tank not completely down Igniter lead disconnected Defective flame controller Gas valve defective Safety thermostat operated or defective Difficult or u...

Страница 14: ...574 COPPER 1BA WASHER FAS658 4 X 30 ROLL HA112 SPOKED HANDWHEEL IG06 IGNITION LEAD IS582 OG8801 BRATT PAN USER INS JE71 BURNER JET G20 NATURAL GAS JE34 BURNER JET G31 PROPANE GAS KN502 OPUS 800 KNOB BRATT PAN LE14 LENS COVER LE14 NE47 AMBER NEON PL209 PLUG LEAD 3 METRE SO27 WATER VALVE NO SP92 LID SPRING SW34 SWITCH CHANGE OVER SW58 FAN SWITCH SW80 GREEN BUTTON SOLID SW82 SWITCH ELEMENT N O SW93 L...

Страница 15: ...IS 582 ECN 3851 Page 15 of 17 900 900 800 770 800 770 is with lid up and flue top removed 900 1600 ...

Страница 16: ...iently as possible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty given reasonable access to the appliance during normal working hours Monday to Friday 08 30 to 17 00 GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty The guarantee is in addition to a...

Страница 17: ...ised technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes of administrative time not spent directly carrying out servicing work is provided for within the warranty Any requirement for staff attending the call to spend greater time than 15 minutes due to ad...

Отзывы: