INSTALLATION
SITING
The installer must ensure that all regulations are met and that there is an unobstructed minimum
distance of 1000mm from the top of the flue to the ceiling, which must be of non-combustible
material.
The appliance should be installed on a level surface ensuring the unit is stable and firmly located.
Any partitions, walls or kitchen furniture in close proximity must be of non-combustible materials
and not be closer than 50mm from the sides and rear of the flue.
GAS SUPPLY AND CONNECTION
The gas inlet connection is at the rear of the appliance. The pipe work should be of adequate size but
not smaller than the gas inlet connection at the rear of the appliance, i.e. Rp ½” BSP (OD7006) &
Rp ¾” BSP (OD7007).
All joints made must be leak free.
Final gas connection to the appliance and gas supply shall comply with local regulations.
When making the connection to the appliance an isolating cock should be fitted into the supply line
close to the unit, for emergency shutdown or servicing purposes.
SUPPLY PRESSURES
The appliance is connected directly to the gas supply where the gas supply pressure is controlled at
the source of inlet in the building or via the governor attached to the bottle gases. See Technical Data
for the supply pressures.
•
To gain access to the gas pressure test nipple the fascia panel requires removal. The test
nipple is situated in the centre of the manifold rail.
•
Remove the blanking screw and attach a pressure gauge to the boss of the test nipple.
•
Light the oven burner and set thermostat to the highest setting and check the pressure.
ELECTRICAL SUPPLY AND CONNECTION
Connection of the electrical supply cable is made at the rear of the unit. Remove the protective cover
and fit a suitable cable into the strain relief and then to the inlet terminal block. The unit is supplied
for connection to a three-phase supply. Connections are provided to allow termination of all three-
phase cables, although only two are used to power the unit. If the unit is to be fed from a single-
phase then the two supply terminals will need to be connected together using a wire link
LOCKING OF WHEELS
When the appliance has been installed in its intended position the front castors should be
locked by depressing the locking tabs on the castors.
Locks should only be released for the intention of moving the appliance for cleaning
purposes and or routine servicing of the appliance.