IS 339 ECN 3607
Page 4 of 11
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed.
The serial plate is located on Fig 1 (F).
Instructions for wall mounting are supplied with the wall mounting kits (see
Accessories).
Model
Power (kW)
Ambient
temperature Deg C
Water inlet
pressure (bar)
Water inlet
pressure (kPa)
EB3F
3.0
5 to 30
1 to 8
100 to 800
EB4F
4.5
EB6F
6.0
EB6TF
6.0
Electrical supply
The EB3F is supplied with a 13 amp plug.
The EB4F is supplied with a bulkhead cable connector. Connect a 2.5mm
2
3 core
cable.
The EB6F and EB6TF are supplied with a bulkhead cable connector. Connect a
4mm
2
single or 3 phase cable.
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of these appliances.
Water supply and waste connection (All)
Connect the supplied white water inlet hose to the inlet connection point on the
base of the boiler and the other end to the mains supply via an accessible isolating
tap with a ¾” BSP thread.
Use the hose set supplied with the appliance - any previous hose set is not to be re-
used.
If required, the drip tray can be connected to a waste water outlet using a ½”
bulkhead connector (not supplied). Knock out the blank in the tray base. If cables