Lincat EB3F Скачать руководство пользователя страница 10

IS 339   ECN 3607

 

Page 10 of 11 

 

 

 
 

Part Number 

Description 

Used on 

CO206 

¼” to 3/8” elbow 

All 

CO215 

Contactor 

All excluding EB3F 

DV02 

Service valve 

All 

EBM05 

Outer lid 

EB3F, EB4F 

EBM08 

Outer lid 

EB6F, EB6TF 

EL235 

Element 3kW 

EB3F, EB6F, EB6TF 

EL241 

Element 4.5kW 

EB4F 

FC02 

Filter cartridge 

All 

FH02 

Filter head 

All 

GA48 

Lid gasket 

EB3F, EB4F 

GA51 

Lid gasket 

EB6F, EB6TF 

LE47 

Level sensor insulator 

All 

LE48 

Upper level sensor 

All 

LE49 

Lower level sensor 

All 

PI12 

Inlet hose 

All 

PL202 

Mains cable 

EB3F 

PR74 

Circuit board 

EB3F 

PR75 

Circuit board 

EB4F 

PR76 

Circuit board 

EB6F, EB6TF 

SL20 

Tap union nut 

All 

SL21 

Tap circlip 

All 

SL29 

Tap 

All 

SO23 

Solenoid valve 

EB4F, EB6F, EB6TF 

SO24 

Solenoid valve 

EB3F 

TH87 

95

o

 cutout thermostat 

All 

TH88 

120

o

 cutout thermostat 

All 

TH98 

Thermistor 

All 

 
 
 

 
 

Part Number 

Description 

Used on 

BR49 

Wall mounting kit 

EB3F, EB4F 

BR50 

Wall mounting kit 

EB6F, EB6TF 

FC02 

Replacement filter cartridge 

All 

 
 
 
 
 
 

SPARE PARTS LIST

 

ACCESSORIES

 

Содержание EB3F

Страница 1: ...Water Boilers EB3F EB4F EB6F EB6TF Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ___________...

Страница 2: ...rmation and Guarantee 11 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and no...

Страница 3: ...Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DA...

Страница 4: ...kPa EB3F 3 0 5 to 30 1 to 8 100 to 800 EB4F 4 5 EB6F 6 0 EB6TF 6 0 Electrical supply The EB3F is supplied with a 13 amp plug The EB4F is supplied with a bulkhead cable connector Connect a 2 5mm2 3 cor...

Страница 5: ...Ensure the metal overflow pipe protrudes through the metal base of the boiler OPERATING INSTRUCTIONS Fig 1 Only qualified or trained personnel should use this appliance First Use Switch on the water...

Страница 6: ...temperature will be displayed Press the power button to cycle through the values 70 96 Deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next Press th...

Страница 7: ...EANING Do not use a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent do not use abrasive materials Dry with a soft cloth Slide out and e...

Страница 8: ...run the boiler normally for 30 minutes Isolate the boiler and allow the water to cool Remove both outer and tank lids again Inspect the tank and level sensor housings for scale deposits If necessary...

Страница 9: ...AR Scale on level sensors Boiler overfilling Descale Check water inlet valve FILTER NO WATER FAULT SEE MANUAL STANDBY CLEAR Water turned off Inlet hose kinked or blocked Water pressure too high or low...

Страница 10: ...sensor insulator All LE48 Upper level sensor All LE49 Lower level sensor All PI12 Inlet hose All PL202 Mains cable EB3F PR74 Circuit board EB3F PR75 Circuit board EB4F PR76 Circuit board EB6F EB6TF S...

Страница 11: ...ot diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bu...

Отзывы: