ELECTRICAL CONNECTION
•
The appliance is equipped with an electrical cable
H05RR-F 3x0.75 mm²
having an
European plug. It is a type “
Y
” connection and therefore any replacement of the cable
must be carried out by a qualified staff only. Feeding
1N 230V AC 50Hz
. The electrical
cable should be disposed in such a way to avoid any contact with hot and sharp parts.
The appliance should be connected with a grounding system.
CONNECTION TO THE HEATING PLANT
•
It’s advisable to read, follow and respect what indicated in the
Section Installation.
Do not use the appliance, if it has not been connected to a heating plant in working
conditions.
Before setting at work the appliance, it is necessary to fill the boiler and to eliminate
possible air bubbles.
The appliance is equipped with a closed 8 lit expansion tank. The installer must
ABSOLUTELY verify the dimensions of the heating plant and, if necessary, replace the
expansion tank with another if the equipped one should not be sufficient.
The appliance is produced with the internal working at closed expansion tank. In case the
appliance is used in pairing with other types of appliances or heating plants, the installer
should prearrange all necessary to solve compatibility problems.
Per.
for the equipped appliances of fast sanitary water(
mod.
940
) is lively advised the
installation of a water softener (also according to the hardness of water system), to avoid
limestone coking in the rapid exchanger that in the long time reduce strongly the
efficiency and therefore the ability to produce warm water
.
•
The installation water should have some chemical and physical characteristics for a good
functioning of the equipment for a long time. The feeding water of bad quality could
cause problems as incrustations of the thermic exchange surfaces and sometimes the
corrosion of water surfaces of the complete circuit. The presence of chalky incrustation
penalize a lot the thermic exchange and dangerous overheating could be caused. Here
follow some examples to make treatment for water :
Water hardnes > di 20°f ;
Heating plan with open expansion tank; Frequent water introduction due to lacks
or maintenance operation.
Call a qualify company for the water treatment of thermic plan.
The equipment is supplied by a new generation Circulator ERP. For safe
installation and right equipment functioning, we recommend installing a Dirt
Separator with Magnet positioned on the return of the installation, upstream of the
circulator apparatus. The lack of an adequate system of filtering, could compromise
the circulator and / or its operation.
Содержание 0000
Страница 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Страница 34: ...IT GB FR mod 940 940 SA 34 112 ...
Страница 35: ...IT GB FR mod 940 940 SA 35 112 ...
Страница 36: ...IT GB FR mod 940 940 SA 36 112 ...
Страница 37: ...IT GB FR mod 940 940 SA 37 112 ...
Страница 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Страница 71: ...IT GB FR mod 940 940 SA 71 112 ...
Страница 72: ...IT GB FR mod 940 940 SA 72 112 ...
Страница 73: ...IT GB FR mod 940 940 SA 73 112 ...
Страница 74: ...IT GB FR mod 940 940 SA 74 112 ...
Страница 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Страница 107: ...IT GB FR mod 940 940 SA 107 112 ...
Страница 108: ...IT GB FR mod 940 940 SA 108 112 ...
Страница 109: ...IT GB FR mod 940 940 SA 109 112 ...
Страница 110: ...IT GB FR mod 940 940 SA 110 112 ...
Страница 111: ...IT GB FR mod 940 940 SA 111 112 Note ...