12
www.lin arie. c om.a u
cont. troubleshooting
1. Failure code that occur when customer is using and Solution;
2. Specific Failure and Solution
Plug in,
No “BI”
heard
*U
*E1
- Is there blackouts?
- Check for damaged fuse and socket.
- Check if cooking vessel suits for the cooker.
- Check if the pot is centered.
- Check if the bottom diameter is not larger
than 12cm.
- Check for low voltage.
*E2
*E3
- Check for high voltage.
- Check sensor open for short-circuits.
The LED does not turn on
when unit is plugged in
Cooking mode indicator
comes on, but heating
does not start.
Fan motor sounds
is not normal
The fan motor
is damaged.
Heating zones of the
same side (Such as the 1st
and 2nd zone) would
display “
Er
”
Ambient temperature may be too high.
Air intake or air vents maybe blocked.
There is something wrong with the fan. Check if the fan is running smoothly. If not,
replace the fan.
Some keys wont work, or
LED dislay is not normal
Heating suddenly stops
and the display
flashes “ ”.
No power supplied.
Accesorial power board and
display board failure.
Check connection.
Check if the outlet is working and tightly secure the plug.
ERROR
FAILURE
PROBLEM
SOLUTION
CHECK POINTS
Accesorial power board is damaged.
Replace the accessorial power board.
The display board is damaged.
The display board is damaged.
Pan type is wrong.
Use a proper pot. (refer to page 7)
Pan detection circuit is damaged.
Pot diameter is too small.
Replace the display board.
Replace the display board.
*E4
*E5
*E6
*Er
- Check IGBT open for short-circuits.
*
IGBT
-
insulated – gate bipolar transistor
, A semiconductor device use to control the load of power supply.
- Surface temperature is higher than 280ºC.
- Check ambient temperature if it is high.
- Signal problem between control pcb and
main pcb.
- Check suction and exhaust outlets and see
if the fan is running.
- Check under warm/ milk section if the set
temperature has been reached.
- Check the protective device if triggered or
not. Wait for 10minutes to confirm.
The power board is damaged.
Power board and display board
connection failure.
Display board communication part is
damaged.
The main board is damaged.
Check connection.
Replace the display board.
Replace the power board.
Replace the fan.
Replace the power board
The induction cooktop is equipped with a self-diagnostic function. With this test the technician is able to check the function of
several components without disassembling or dismounting the cooktop from the working surface.
High temperature of the cooktop.
GENERAL INFORMATION
Allow the appliance to cool down completely before cleaning and maintenance.
The surface and controls are susceptible to scratches and abrasion. Please observe the following cleaning instructions.
Observe all safety and warning information during operation (see the “General Safety Instructions” section).
WARNING
If you have completed the above check and still having difficulty, please contact
your local Linarie Service Center. See “Warranty and Spare parts section”.
Before maintenance or cleaning, the appliance should always be disconnected from the power supply. Make sure that
the appliance is switch off and the plug has been removed. Exterior surfaces are prone to scratches and dents. Therefore,
please follow the cleaning instructions to achieve the best possible result without damage.