Linak Homeline TWINDRIVE TD5 Standard Скачать руководство пользователя страница 14

Page 14 of 31

Misc. on the TWINDRIVE

®

 TD5 Standard system

This system is a TWINDRIVE system developed for leisure beds and for indoor use in private homes. 

Warranty

There is 36 months’ warranty on the TWINDRIVE

®

 products against manufacturing faults calculated from the production 

date of the individual products (see label). The LINAK

®

 warranty is only valid in so far as the equipment has been used and 

maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment. In 
the event of this, the warranty will be ineffective/invalid. For further details, please see standard terms of sale and delivery for 
LINAK A/S.

Maintenance

Clean dust and dirt on the outside of the system at appropriate intervals and inspect them for damage and breaks.
Inspect the connections, cables and plugs and check for correct functioning as well as fixing points. 

The cleaners and disinfectants must not be highly alkaline or acidic 
(pH value 6-8).

It is not allowed to use solvents for cleaning up.

Max. load running back and leg end motors at the same time in upward direction is 7000 N on back 
motor, and 7000 N on leg end motor. 

For customers in the US/Canada:

The mains cable for this product has a polarised plug (one blade is wider than the other). It will only fit in a polarised 
outlet one way. If it does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician 
to install a proper outlet. Do not change the plug in any way.

Description of the TWINDRIVE

®

 TD5 Standard system

Each TWINDRIVE

®

 TD5 Standard unit consists of 2 internal motors and a built-in control box, which makes it a very compact 

unit. The mains cable is exchangeable. Only the handset must be paired.

Application of the TWINDRIVE

®

 TD5 Standard system:

Irrespective of the load the 

Duty cycle: 10 % ~ max. 1 minute at continous use followed by 9 minutes not in use.

Do not turn on the system if it is not mounted in a bed.

TD5 is a Bluetooth

®

 based system, which means you can use hand controls based on Bluetooth

®

LINAK

®

 offers a range of compatible hand controls: HC05BL, HC10BL and HC40BL. Alternatively, the Bed Control App can be 

downloaded to use a smartphone as handset. 

You can pair eight hand controls to one TD5. You can also pair both hand controls and app controls to the same TD5 Standard, 
but only eight controls in total. If you pair more hand controls than the TD5 Standard can manage, the first paired hand control 
will be deleted. 

This user manual will give you a detailed description on how to pair your hand controls with your TD5 Standard. 

Содержание Homeline TWINDRIVE TD5 Standard

Страница 1: ...Page 1 of 31 LINAK COM HOMELINE TWINDRIVE TD5 Standard User manual...

Страница 2: ...ulement pour les march s hors UE 12 Utilisation abusive 12 Repairs 13 Misc on the TWINDRIVE TD5 Standard system 14 Description of the TWINDRIVE TD5 Standard system 14 Mounting the TD5 Standard 15 Cabl...

Страница 3: ...eave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK sub...

Страница 4: ...th the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and a...

Страница 5: ...e is only to be used with the power supply unit provided with the appliance Safety issues The builder of the equipment shall ensure that the use of the component complies with relevant standards like...

Страница 6: ...tested and found to comply with the limits for a Class B diwgital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in...

Страница 7: ...nnovation Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any...

Страница 8: ...nnecting to the mains During operation If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mob...

Страница 9: ...knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surveilla...

Страница 10: ...ment suivies Le non respect de se conformer aux instructions marqu es du symbole note peut entra ner de graves dommages au syst me ou un de ses composants Il est important pour tout individu qui conne...

Страница 11: ...ontr le est correcte avant que le syst me soit connect sur le secteur Syst me de connection Les diff rentes pi ces doivent tre connect es entre elles avant que le bo tier de contr le soit connect au s...

Страница 12: ...essaires sur le ou les produit s ne doivent pas le ou les utiliser Par ailleurs les personnes ayant des capacit s physiques sensorielles ou mentales r duites ne doivent pas utiliser le ou les produit...

Страница 13: ...of malfunction all TWINDRIVE repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted TWINDRIVE under warranty must...

Страница 14: ...mains cable for this product has a polarised plug one blade is wider than the other It will only fit in a polarised outlet one way If it does not fit fully in the outlet reverse the plug If it still d...

Страница 15: ...he closing devices mounted The bed brackets must have a smooth surface without burs and welding blops in the area where the TD5 is mounted It is important to turn the key in the direction indicated on...

Страница 16: ...the cable relief on the TD5 By using the relief you avoid that the mains cable plug is pulled out of the TD5 resulting in a malfunction Depending on the thickness of the cable you can choose to lead...

Страница 17: ...tons on LINAK hand control at the same time The Under Bed Light gives one long flash to indicate that the hand control and the TD5 are paired up The TD5 stays in pairing mode and it is possible to con...

Страница 18: ...ed Control App will automatically pair to the closest TD5 in pairing mode Wait a few seconds to see app confirm completed pairing 6 Smartphone tablet and TD5 are now paired up App will display operati...

Страница 19: ...ired Forced pairing mode You can also pair a new device by using the forced pairing mode 1 Turn on Under Bed Light 2 Disconnect from mains 3 Wait until Under Bed Light turns off 4 Reconnect TD5 to mai...

Страница 20: ...ide of TD5 Underneath the TD5 are two gaps for mechanical lowering 3 Place hex key in gap one end at a time and turn hex key in direction indicated by arrow It is important to turn the key in the dire...

Страница 21: ...Page 21 of 31 TD5 Twist Bracket Mounting instructions and parallel tolerance When bed is horizontal starting position The diameter of the shaft must be 25 2 mm 0 2 0 3...

Страница 22: ...t and the foot rest it is important that the Twist bracket is mounted and welded according to the above instructions Non compliance with the instructions could lead to a smaller angle of rotation or i...

Страница 23: ...otor Up down leg motor Common operation up down option Light Button Hand Control HB10 Wireless Hand Control HC05 Wireless Hand Control HC10 Wireless Up down back motor Up down leg motor Common operati...

Страница 24: ...Page 24 of 31 Label for TD5 Standard Label for HC05BL Label for HB10BL Label for HC40 FRAMETM Standard Label for HC40 TWISTTM Standard Label for HC10BL...

Страница 25: ...eel Plastic can e g be divided into ABS PA PE and PP As an example of sorting please find below a list stating in which recycling groups the different components of LINAK products ought to be placed B...

Страница 26: ...e or in nature This will cause damage to the enviroment How to deal with leaking batteries Leaking batteries should be disposed as described above If leaking batteries are discovered in the product th...

Страница 27: ...Page 27 of 31 DRAWING APPENDIX TWINDRIVE TD5 Standard system...

Страница 28: ...Page 28 of 31 Hand Control HC05BL 13 5 34 100 2 9 1 3 Drawing No HB12RF0100_SALG 140 47 14 Drawing No HB12RF0100_SALG Hand Control HB10BL Hand Control HC10BL By d By SCALE 1 2 Drawing No HC10_BATTERY_...

Страница 29: ...Page 29 of 31 HC40 FRAMETM Standard HC40 TWISTTM Standard 46 169 4 15 3 Created By Bjarne Skov 2019 04 12 46 169 4 15 3 Created By Bjarne Skov 2019 04 12...

Страница 30: ...nder which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditio...

Страница 31: ...334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www mem net co India Mechatronics Control Equipments India Pvt Ltd Phone 91 44 28558484 85 E mail bala mechatronicscontrol com www m...

Отзывы: