10
2.
Set the rotary switch to diode position.
3.
For forward voltage drop readings on any semiconductor compo-
nent, place the red test lead on the component’s anode and
place the black test lead on the component’s cathode.
The measured value shows on the display.
Continuity test
(see fig 3)
To test for continuity, connect as follows:
1.
Insert the red test lead into the V
Ω
mA terminal and the black test
lead into the COM terminal.
2.
Set the rotary switch to continuity position.
3.
Connect the test leads across with the object being measured.
The buzzer sounds if the resistance of a circuit under test is less
than 70
Ω
.
Temperature measurement
(see fig 4)
1.
Insert the red temperature probe into the V
Ω
mA°C°F terminal
and the black temperature probe into the COM temperature.
2.
Set the rotary switch to °C or °F position.
3.
Place the temperature probe to the object being measured. The
measured value shows on the display.
Note
•
The Meter automatically displays the temperature value inside
the Meter when there is no temperature probe connected.
•
The included point contact temperature probe can only be used
up to 250 °C(482°F).
•
The temperature function is type K. For measuring higher tempe-
ratures other probes of type K can be used together with a multi
socket.
3 0 0