English

Safety Information 

This Meter complies with the standards IEC61010: in pollution degree 2, category CAT III 1000V, 

CAT IV 600V over voltage and double insulation.

Warning 

To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or 

to the equipment under test, adhere to the following rules:. 

• Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or 

part of the case) is removed. Look for cracks or missing plastics. Pay attention to the insulation 

around the connectors. 

• Inspect the test leads for damages insulation or exposed metal. Check the test leads for 

continuity. 

• Do not apply more than the rated voltage, as marked on the Meter, between the terminals or 

between any terminal and the grounding. 

• The rotary switch should be placed in the right position and no any changeover of range shall be 

made during measurement is conducted to prevent damage of the Meter. 

• When the Meter working at an effective voltage over 60V in DC or 42V rms in AC, special care 

should be taken for there is danger of electric shock. 

• Do not use or store the Meter in an environment of high temperature; humidity, explosive, 

inflammable and strong magnetic fields. The performance of the Meter may deteriorate after 

dampened. 

• When using the test leads, keep your fingers behind the finger guards. 

• Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, 

continuity, diodes and current. 

• Before measuring current, check the Meter fuses and turn off power to circuit before connecting 

the Meter to the circuit. 

• Replace the battery as soon as the battery indicator appears. Whit to low battery, the Meter 

might produce false readings that can lead to electric shock and personal injury. 

Functional buttons 

RANGE 

• Selection auto range or manual rangeing.The instrument always start with 

auto range. In auto range the instrument always select the best range for input 

signals. 

  

Display shows AUTO.  

 

• Push button to step through the ranges available for selected function. Push button 

2 sec to return to auto range.  

MAX/MIN

  • Select max or min value. Push button for 2 sec for exit max/min function. 

REL

• Relative mode applies to all function except frequency/duty cycle. Displays shows 

 when relative function is on. 

 

• On/Off for enter USB connection to PC. Push button for 2 sec for enter or exit. 

Hz% 

• Select measuring frequency in Hz or duty cycle in % when rotary switch is in Hz 

position.

 

• When measuring V, µA, mA or A also frequency or duty cycle can be displayed 

 

by push the Hz% button. Push button by step between frequency, duty cycle or 

return to previous measurement mode. 

Yellow

 

• ON/OFF for hold function. H shows on display when value is frozen. 

 

• ON/OFF for backlight. Push button for 2 sec for backlight. 

Blue

 

• Selection of function when there are more than one function for rotary switch. 

Содержание 153220108

Страница 1: ...1 Illustrations Fig 4 Fig 5 Fig 6 Fig 3 Fig 2 Fig 1 ...

Страница 2: ...Tables ...

Страница 3: ...Tables ...

Страница 4: ...Tables ...

Страница 5: ...2 610 English 3 Svenska 8 Norsk 12 Dansk 16 Suomi 21 Deutsch 25 Netherlands 31 Français 36 Italiano 41 Español 46 Português 51 Ελληνικά 56 Polski 62 Eesti 68 Lietuviškai 73 Latviski 79 Pycckий 84 ...

Страница 6: ...nts of non linear signals Reading of Max and Min value Can be connected to PC for transfer data General Specifications Measuring range and accuracy see page 2 Fused Protection for V mA Input Terminal 1 A 250V fast type 6x25 mm Fused Protection for 10 A Input Terminal 10 A 250V fast type 6x25 mm Auto range or manual ranging True RMS for voltage and current measurements Analogue bar graph 61 segment...

Страница 7: ...ehind the finger guards Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity diodes and current Before measuring current check the Meter fuses and turn off power to circuit before connecting the Meter to the circuit Replace the battery as soon as the battery indicator appears Whit to low battery the Meter might produce false readings that can lead...

Страница 8: ...or himself may be hurt Use proper terminals function and range for the measurement When the testing leads are connect ed to the current terminals do not parallel them across any circuit If the current is more than 5 Amp Measuring time for current should be less than 10 sec and interval time between measurement should be 15 minutes To measure current connect as follows 1 Turn off power to the circu...

Страница 9: ...ch to continuity position blue 3 Push blue button to select continuity function Displays shows continuity symbol 4 Connect the test leads across with the object being measured The buzzer sounds if the resistance of a circuit under test is less than 70ȍ Capacitance measurement See fig 5 1 Insert the red test lead into the HzVȍ terminal and the black test lead into the COM terminal 2 Set the rotary ...

Страница 10: ...uit under test when battery indicator appears on the display 2 Turn the Meter to OFF position 3 Remove the screw and separate the case bottom from the case top 4 Replace the battery with a new 9V battery type 6F22 5 Rejoin the case bottom and case top and reinstall the screw Replace the fuses See figure 6 1 Disconnect the connection between the testing leads and the circuit under test 2 Turn the M...

Отзывы: