background image

4

SAFETY & 

CLEANING 

INSTRUCTIONS

DO’s

STORAGE & TRANSPORTATION

DON’Ts

Follow all instructions.
Keep these instructions.
Heed all warnings.

Do not install near any heat sources, 
do not expose the product to flames 
or use near naked flame sources.
Do not use flammable solvents near or 
on this product.

Only use the lubricant and 
simulated blood supplied with this 
product. Use of non-recommended 
fluid products may weaken or 
damage the simulator.

Do not use any attachments 
other than those supplied by the 
manufacturer.

Wear gloves at all times and remove all 
jewellery items. Sharp surfaces such as 
finger nails and rings can lead to damage 
of silicone parts.

Clean the product with a damp soft 
cloth or sponge, using only warm water 
with mild detergent, after every training 
session. Clean off excess lubricant from all 
mother and baby surfaces.

Always ensure that the products are 
properly packed and secured during 
transportation and storage in order to 
prevent personal injury or damage to 
the product.

Do not wear any jewellery items.

Do not disassemble the product or 
attempt to repair a faulty unit, please 
return the product to Limbs & Things 
for assessment and repair.

READ THE SAFETY INSTRUCTIONS CAREFULLY BEFORE 

USING YOUR BIRTHING SIMULATOR PROMPT FLEX

Always lubricate the cervix, birth 
canal and baby before each birth. 
A poorly lubricated baby or placenta 
may damage the birth canal or the 
cervix as it is pushed through.

Do not use if the skin is torn.

Lubricant

 

Gel

Содержание ECOSystem 80197

Страница 1: ...R MORE SKILLS TRAINING PRODUCTS VISIT Sussex Street St Philips Bristol BS2 0RA UK sales limbsandthings com 44 0 117 311 0500 USER GUIDE ECOSystem with PROMPT Flex 80197 80297 80198 80298 80199 80299 SMALL INTERMEDIATE LARGE ...

Страница 2: ...com limbsandthings INDEX PACKAGE SUPPLIED 3 SAFETY CLEANING INSTRUCTIONS 4 SET UP 5 REMOVING THE ABDOMINAL SKIN 5 REMOVING THE CERVIX 6 SETTING UP DIFFERENT STATIONS 7 TRAINING 8 SHOULDER DYSTOCIA 8 POSTPARTUM HEMORRAGE 9 EXTENDED BREECH BIRTH 10 UMBILICAL CORD PROLAPSE 11 CLEANING STORAGE 11 ...

Страница 3: ...mulator PROMPT Flex Advanced ü ü ü 80112 80212 Postpartum Hemorrhage Kit PROMPT Flex ü ü ü 80120 80220 Birthing Simulator PROMPT Flex û û ü 80124 80224 Abdomen for PROMPT Flex û û ü 80196 Piper Forceps ü ü ü What s included iPad not included Download app at limbsandthings com Postpartum Hemorrhage Kit includes 80101 80201 PPH Module PROMPT Flex 80111 Compression Suture Uterus x2 80171 80271 Pre in...

Страница 4: ... of silicone parts Clean the product with a damp soft cloth or sponge using only warm water with mild detergent after every training session Clean off excess lubricant from all mother and baby surfaces Always ensure that the products are properly packed and secured during transportation and storage in order to prevent personal injury or damage to the product Do not wear any jewellery items Do not ...

Страница 5: ...5 SET UP REMOVING THE ABDOMINAL SKIN The abdomen can be removed easily to facilitate correct positioning of the baby within the pelvis if necessary 1 2 ...

Страница 6: ...6 SET UP REMOVING THE CERVIX 1 The Cervix will need to be removed when conducting a SHOULDER DYSTOCIA drill BREECH PRESENTATION VAGINAL DELIVERY PPH and UMBILICAL PROLAPSE 2 3 ...

Страница 7: ...GINAL DELIVERY 4 UMBILICAL CORD PROLAPSE 2 POSTPARTUM HEMORRHAGE SETTING UP THE DIFFERENT STATIONS There are 5 teaching stations in total for ECO with the 5th being communication The Limbs Things ECOSystem offers all the equipment needed to run the course ...

Страница 8: ...items Always lubricate the birth canal and baby before each birth Lubricant Gel REMOVE THE CERVIX The trainer needs to ensure that the anterior shoulder of the baby is wedged behind the symphysis pubis The baby must be held in this position by the trainer when delivery commences ...

Страница 9: ...9 Remove the cervix and place the PPH Module to the Birthing Mother Attach the connectors See PPH User Guide for a more detailed information TRAINING POSTPARTUM HEMORRHAGE User Guide ...

Страница 10: ...h canal and baby before each birth To conduct a breech delivery the trainer needs to push on the head to simulate contractions and maternal effort Ensure the baby s arms remain flexed during the delivery unless nuchal arms are required for training You ll need included PIPER FORCEPS Lubricant Gel REMOVE THE CERVIX ...

Страница 11: ...each birth TRAINING UMBILICAL CORD PROLAPSE It is vitally important that after each training session all lubrication is cleaned from all mother and baby surfaces with a warm damp cloth You can also use the supplied baby wipes to wipe away any excess lubricant CLEANING STORAGE Lubricant Gel REMOVE THE CERVIX ...

Страница 12: ... 03 February 2022 2022 Limbs Things Simulation Session Plan 80197 SMALL ECOSYSTEM 80198 80199 INTERMEDIATE ECOSYSTEM LARGE ECOSYSTEM STATION 1 STATION 1 3 4 STATIONS SIMULTANEOUSLY STATION 2 4 STATION 2 STATION 3 STATION 4 ...

Отзывы: