ZL-R200A Heat Pump Water Heater Controller 

Instruction Manual V1.0

c

 

 

Main Function 

Auxiliary heating function 
Water flowing warning 
Ventilation pump control 
Antifreeze function 
Sensor failures action 

Auto defrost function 
Auto restart function 
Exhaustion temperature protection 
Compressor delay and pressure protection 

 

Technical Specification 

Sensor:   

NTC 10K/3470   

Set range:   

20

 ~ 

60

   

Display range:   

-40

 ~ 

130

   

Working temperature: 

0

 ~ 

50

 

Storage temperature: 

-10

 ~ 

60

 

Ambient humidity: 

20

 ~ 

85%RH without dew 

Power supply:   

220Vac ±10% 50/60Hz 

Load:   

Compressor 15A 
Heating 8A 
Others 3A 

 

Failure Code 

No. 

Code 

Failure 

No. 

Code 

Failure 

E01 

Water container sensor failure 

E05 

Water flow warning 

E02 

Pipe Coil sensor failure 

E06 

High/low pressure input warning 

E03 

Exhaustion sensor failure 

E07 

Data saving failure 

E04 

Outdoor sensor failure 

E08 

Communication failure

 

 

 

Display Indication 

Icon 

Display 

Not shown 

Icon 

Displaying 

Not shown 

 

Online 

Offline 

 

Compressor running  Compressor stop 

 

Heating 

Not heating 

 

Pump running 

Pump stop 

 

Electrical heating 

Electrical heater off 

 

 

Four valves on 

Four valves off 

 

Outdoor fan running 

Outdoor fan stop 

 

Locked 

Unlocked 

 

Defrosting 

Not defrosting now 

 

 

 

 

 

Key Operation 

Temperature Inquiry 

Press 

 

key to check all sensor

s’ temperature consecutively. The result keeps displaying for 3 seconds. 

 

Содержание ZL-R200A

Страница 1: ...mpressor 15A Heating 8A Others 3A Failure Code No Code Failure No Code Failure 1 E01 Water container sensor failure 5 E05 Water flow warning 2 E02 Pipe Coil sensor failure 6 E06 High low pressure input warning 3 E03 Exhaustion sensor failure 7 E07 Data saving failure 4 E04 Outdoor sensor failure 8 E08 Communication failure Display Indication Icon Display Not shown Icon Displaying Not shown Online ...

Страница 2: ...High low pressure warning mode 0 2 0 Disable 1 Closed when warning 2 Open when warning 0 9 U52 Water flowing switch mode 0 2 0 Disable 1 Effective when closed 2 Effective when open 0 10 U80 Auto restart function 0 1 0 Disable 1 Enable 0 11 U81 Keypad lock 0 1 0 Unlocked 1 Locked 0 12 U90 passwords 00 99 11 Working Mode Press to switch between AUTO and SAVE working mode AUTO mode always heating acc...

Страница 3: ...pressor and outdoor fan stop 55 seconds later valve acts 5 seconds later start compressor Stop defrosting When T pip U32 or the compressor has been running for U33 stop defrosting Stop compressor 55 seconds later valve acts 5 seconds later start heating control Defrost after turning the system online When turn online if the T pipe U31 defrost 1st Timer Defrost If pipe sensor fails and the compress...

Страница 4: ...tly otherwise system does not work correctly The real clock can only keep running correctly for 72 hours after power supply loses All sensors must be installed at correct position Do not plug in out panel bundle with power supplied Panel should be installed indoors instead of outdoors ...

Отзывы: