Press

or

to select the parameter code (see parameter code table below). 

Press

S

  to display the value of the code. 

Press

or

to set the value. 

Press

S

to return to parameter code selection.   

Keep

P

depressed for 3 seconds to exit, and save the settings.   

The status will exit, and the settings will not be saved, if no key operation for 30 seconds. 

Parameter Code Table 

C

o

d

e

 

 

 

Function 

Range 

Remark 

F

a

c

to

ry

 

D

e

fa

u

lt 

U10  Minimum time for Temp. Output to keep de-energized   

0 ~ 100 min 

Only for cooling 

U20  Sensor calibration 

-9.9 ~ +9.9

 

 

0.0 

U22  Hysteresis for temperature control 

0.1

 

~

 

+10.0

 

 

0.1 

U40  Timer period 1, time unit 

0 ~ 2 

0: sec; 1: min; 2: hour 

U41  Timer period 1, time 

1 ~ 9999 

R2 on 

30 

U42  Timer period 2, time unit 

0 ~ 2 

0: sec; 1: min; 2: hour 

U43  Timer period 2, time 

1 ~ 9999 

R2 off 

60 

U44  R2 working mode   

1 ~ 2 

1: Timer output   

2: Timer  limit_protection 

U45  Timer repeat times   

0 ~ 9999   

If 0: Timer never stops 

Else: R2 never on, when U46 reaches U45   

U46 

Timer counter   

(the value saved to permanent memory once every hour, 

keeps even without power supply) 

0 ~ 9999 

One period = timer period 1 + timer period 2 

Clear to 0 before every hatching 

U52  Over temp. warning delay 

0 ~ 180 min 

 

U53  1

st

 over temp. warning delay after power supplied 

0 ~ 180 hour 

0: disable 

U54  Temp. up limit (relative value) 

0.0 ~ 120.0

 

Absolute point = (Set-point + U54) 

0.2 

U55  Temp. low limit (relative value) 

0.0 ~ 120.0

 

Absolute point = (Set-point – U55) 

37.8 

U60  External input warning mode 

0 ~ 4 

0: disable              3: NC, locked 

1: NO, locked        4: NC, unlocked 

2: NO, unlocked 

U61  Delay for external input warning 

0 ~ 120 min 

 

U62  Buzzing warning 

0 ~ 1 

0: no waring / 1: enable warning 

U90  Control mode 

CO/HE 

CO: cool / HE: heat 

HE 

U99  Password 

0000 ~ 9999 

When 0000, equals no password 

0000 

Note: 

    Limit Protection: 

    Troom: Temperature of the room. SP: Temperature set point. 

    When U44 = 2:   

If Troom 

 SP + U54 in heating mode (U90 = HE), 

or 

if Troom 

 SP - U55 in cooling mode (U90 = CO), 

Then R2 will be energized. 

 

 
 
 
 
 
 
 

Содержание ZL-6231A

Страница 1: ...lure Has failure Warning No warning Has warning R2 output R2 energized R2 de energized Egg turn times reached After reached stop egg turn Display Remark E01 Sensor failure short or open Hi Room temp is higher than the high limit Lo Room temp is lower than the low limit EE Memory error Err Password error i iA A E Ex xt te er rn na al l w wa ar rn ni in ng g U Un nL L Parameters Will restore to fact...

Страница 2: ...it_protection 2 U45 Timer repeat times 0 9999 If 0 Timer never stops Else R2 never on when U46 reaches U45 0 U46 Timer counter the value saved to permanent memory once every hour keeps even without power supply 0 9999 One period timer period 1 timer period 2 Clear to 0 before every hatching 0 U52 Over temp warning delay 0 180 min 0 U53 1st over temp warning delay after power supplied 0 180 hour 0 ...

Страница 3: ...ailure or external warning input If U62 0 no buzzing warning If U62 1 there will be continuous buzzing of warning The waring will stop if press P or warning condition disappears Over Temperature Warning When Troom SP U54 or Troom SP U55 display warning and buzzing External Warning Input NO normal open If open no warning if closed warning NC normal close If closed no warning if open warning Locked ...

Страница 4: ...dule as load or tungsten lamp or motor following the below requirements to avoid surging current damaging or shorten the life time of the controller outputs For ac dc module as load the rated current should be no more 1 10th of output specification under pure resistance For tungsten lamp as load the rated current should be no more 1 15th of output specification under pure resistance For motor the ...

Отзывы: