Suzhou Lily Tech. Co., Ltd.
[email protected] www.suzhoulily.com.cn Page 2, Total pages 5
8
Err
Password error or max/min temperature set invalid
9
iA
External warning
10
dEF
Defrosting now
11
Frd
Forced cooling
12
UnL
Restore the default password ”11”
4.2 Keypad Operation
Set Max and Min Temperature
●
Press
【
SET
】
, MAX TEMP LED will be on, and the digits will show the current max temperature.
Press key
【
▲
】
or
【
▼
】
to change the max temperature setting.
Press
【
SET
】
again, we can set the min temperature limit.
Keeping depressing
【
SET
】
for 3 seconds, or do not press any key for 30 seconds, the device will leave
the temperature testing mode.
●
The factory setting: max temperature is -15
, min temperature is
℃
-18
.
℃
●
The MAX TEMP must be higher than the MIN TEMP
1℃,
otherwise could not be saved.
Note: Only after the
【
SET
】
being depressed for three seconds, will the set data be confirmed and saved.
4.3 Set System Parameters
Enter Into System Parameter Setting Mode
Keep depressing
【
SET
】
for three seconds, digits show “POO”. Input pa
【
SET
】
. If correct,
enter into the mode, else return.
After enter into the mode, the display shows “U01”. Press
【
▲
】
or
【
▼
】
to select the parameter code.
Press
【
SET
】
will show the parameter value. Then press
【
▲
】
or
【
▼
】
to set this parameters, and
press
【
SET
】
to return.
The factory setting: password is “11”.
Exit the Mode
Keep depressing “SET” for three seconds, the set parameters will be saved, the mode exits.
Or do not press any key for 30 seconds, the mode exits, and the set parameters are not saved.
Parameter Code and Description Table:
N
o.
Parameter code
Function
Range
Explain
Factory
setting
1
U10
Compressor power on delay time
1
~
100min
3
2
U11
Compressor MIN continuous work time
0
~
100min
3
3
U12
Compressor run frequency
0
~
8
0: Disable
5
4
U20
Room temperature sensor calibration
-9.9
~
+9.9
0
5
U21
Defrosting sensor calibration
-9.9~+9.9
0
6
U30
Defrosting cycle
0~180 hour
0: Not defrost
12
7
U31
Defrosting
﹙
end
﹚
time
1
~
180min
30
8
U32
Defrosting end temperature
0.5
~
5
0
℃
15
9
U33
Dropping water time
0
~
180min
5
10
U34
Over temperature warning delay time
after defrost ends
0~180 hour
0: Disable
2
11
U35
Defrost when the device starts
0~1
0: Disable
1:Enable
0
12
U36
Defrost delay time when the device start
0
~
180min
0: Disable
0