For connecting D/N HD IP Camera series to the network, please follow one of the
system architectures:
(1). Use DC12V power adaptor and network switch connected to a network.
System Architectures
PC
LAN
LAN / Internet
Non-PoE Switch
DC12V Adaptor
HD IP CAMERA
FIG.18
PoE Switch
PC
LAN
LAN / Internet
(2). Use with PoE of the network switch connected to the network.
HD IP CAMERA
(3). Use PoE power injector and the network switch connected to the network.
PoE Power Injector
PC
LAN
LAN / Internet
AC
Non-PoE Switch
LAN
HD IP CAMERA
Before accessing the IP camera, make sure that the camera's RJ-45 network,
audio, and power cables are properly connected. To set the IP address, consult
your network administrator for an available IP address. The default IP address for
each IP camera is 192.168.0.200. Users can use the default IP address for
verifying the camera's network connection.
Before Accessing IP Cameras
Universal ActiveX software components are required for web interface display of
JPEG or Full HD video. When you login to the IP camera by Internet Explorer, the
security warning dialog box will prompt the installation of the Universal ActiveX.
Click
Install
to download it.
Software Requirements
To change the settings of the IP address, subnet mask, gateway, or HTTP port,
you can follow the steps below:
1. Run the IPScan software.
2. Click
Refresh
. All available devices should be listed in the device list.
3. Select your device from the list provided.
4. Change the IP address, subnet mask, gateway, or HTTP port for the IP camera.
5. Click
Apply
to submit the settings.
6. Click
Refresh
to verify the settings.
Configuring IP Addresses with IPScan Software
To restore the hardware to factory default settings, please follow these steps:
1.Press and hold “RESET Key” for 10 seconds and release.
2.Wait for about 40 seconds, and the network LED light should turn off, and go
back on again.
3.The camera is now restored to factory default settings, and will reboot
automatically.
4.Search for the IP device using the IPScan software.
5.Start the IP device via an Internet browser.
6.Enter the default username “admin” and password “pass” to operate.
For your convenience, the IP address will revert to the default setting
of 192.168.0.200.
NOTE:
Emergency Factory Default
To change an IP address via web interface, type the default IP address
(192.168.0.200) in the Internet browser and follow the steps below:
1. Login to the Full HD IP camera by the default username “admin” and default
password “pass”.
2. Click
Basic Mode
configuration hyperlink.
3. Click
Network->General
hyperlink
.
4. Change the IP address, subnet mask, gateway, or HTTP port for the IP camera.
5. Click
Submit
to verify the settings.
Configuring IP Addresses via Web Interface
Make sure your Internet browser allows the signed ActiveX plug-in to work on
your computer. Set “Download Signed ActiveX plug-in controls” to “Prompt”
and “Run ActiveX control and plug-in” to “Enable”. You can set this option via
Internet Explorer-> Tools-> Options-> Security Settings.
Internet Browser Settings & Application Required
Once complete, you can access the IP
camera's live video by entering the
default IP address via your Internet
browser. As the security warning dialog
box appears, click
OK
to download the
ActiveX directly from the IP camera.
Login
To logon the FULL HD IP camera, please type username and password in
logon HTML page and click on Submit button to enter the system.
The default usernames and
passwords are as follows:
Username
admin
Password
pass
Administrator
FIG.17