background image

Laundering: 

See the sling´s product label.

Product 

Prod. No.   Prod. No. 

Size  

 

Body Weight kg* 

Maximum load 

TeddyVest 

3560812 

 

XXS  

 

< 20 kg (< 44 lbs.) 

200 kg (440 Ibs.)

TeddyVest 

3560813 

3564813 

XS  

 

 20-40 kg (44-88 lbs.) 

200 kg (440 Ibs.)

MasterVest 

3560 - 13 

 

XS 

 

20-40 kg (44-88 lbs.) 

200 kg (440 Ibs.)

MasterVest 

3560 - 14 

3564 - 14 

S  

 

40-60 kg (88-132 lbs.) 

200 kg (440 Ibs.)

MasterVest 

3560 - 15 

3564 -  15 

M  

 

60-80 kg (132-176 lbs.) 

200 kg (440 Ibs.)

MasterVest 

3560 - 16 

3564 -  16 

L  

 

80-100 kg (176-220 lbs.) 

200 kg (440 Ibs.)

MasterVest 

3560 - 17 

 

XL  

 

100-130 kg (220-286 lbs.) 

300 kg (660 Ibs.)

MasterVest 

3560 - 18 

 

XXL 

 

       120-       kg (264-       lbs.) 

300 kg (660 Ibs.)

MasterVest 

  

3564 - 17 

XL  

 

100-130 kg (220-286 lbs.) 

200 kg (440 Ibs.)

MasterVest 

  

3564 - 18 

XXL 

 

       120-       kg (264-       lbs.) 

200 kg (440 Ibs.)

Overview Liko MasterVest, Mod. 60, 64

Code:

1  Recommended
  Possible
3  Not advisable
4  Inappropriate

           Class I medical-technical product

The above table gives several recommendations for each size. Different sling bar widths create different levels of pressure on the chest. 

 

Try various alternatives until you find the one best suited to the individual patient.

Combinations with Liko MasterVest and Cross-bar, Cross-bar 450/670 or Side bars is not appropriate.

© Copyright Liko 

AB 2010-09

0 Liko MasterVest  

 

4 Liko MasterVest, front closure

1 Polyester  4 Plastic-coated net (can be wiped clean and disinfected with alcohol)  8 Teddy bear patterned polyester

356 - - 16

Order number example

:

 

Prod. No. 3560115 

                 

            Liko MasterVest, Polyester, Medium.

Size

*  

NOTE! The body weights given are general recommendations only. Variations are normal.

      Important!

  

Lifting and transferring a patient always involves a degree of risk. 

Study the instruction guides for both lift systems and accessories 

carefully. A complete understanding of the contents of instruction 

guides is essential.  

Only trained personnel should use the equipment.  

Make certain that the lift accessories are appropriate for the lift 

you are using and for the lifting situation. Exercise caution and 

care when using lift equipment and accessories.

As a caregiver, you are responsible for the patient’s safety.  

You must be well informed of the patient’s condition and ability 

to manage the lifting situation.
Inspect the sling regularly, especially after laundering. Check 

carefully for wear and damage to seams, fabric, straps and 

strap loops. Never use damaged accessories! When in doubt, 

contact the manufacturer or supplier. 

 

Liko MasterVest has been tested by an accredited testing institute and complies with all requirements for MDD Class I products and 

the harmonized EN ISO 10535 standard.

Recommended combinations  

using Liko MasterVest  

with Liko sling bars:

Mini 

0

Slim 350

Standard 450

Twinbar 670

Universal 350

Universal 450

Wide 670

Leg Harness, pair 

XS, S 

3666004 

 

Leg Harness, pair 

M, L 

3666005 

3666008 

 

 

Leg Harness, pair 

XL 

3666006 

3666009 

 

NOTE! The leg harness fits vests from serial number 

736166. Contact Liko for information on earlier models.

Liko's products are constantly being updated and refined. Liko reserve the right to change aspects of the products without prior 

notice. Contact your local Liko representative for updated information and advice.

Light green 

Dark green

TeddyVest, XXS   

 

 

 

 

 

 

TeddyVest, XS  

 

 

MasterVest, S

  

 

 

 

MasterVest, M  

 

 

 

MasterVest, L 

  

 

MasterVest, XL

   

 

 

MasterVest, XXL 

  

 

 

Manufacturer: 

Liko AB 

SE-975 92 Luleå

Sweden

[email protected]

www.liko.com

Expected Life Time

The product has an expected life time of 1-5 years with normal use. Expected life time varies depending on the fabric, use frequency, 

washing procedure, and weight carried. 

Periodic Inspection

The product must be inspected at least once every 6 months. More frequent inspections might be required if the product is used or 

washed more often than normal. See Liko’s protocol Periodic Inspection for the respective product.

Universal 600