SMAX MODBUS®
If you set a value greater than the maximum resolution allowed, after sending
the Request PDU the
error message will be sent back
Wrong parameters list [0003 hex]
set to 1.
Default = 10 (min. = 10, max. = 125)
NOTE
If you have set the preset, when you change the value next to the
parameter, then you must check the value in the
parameter and perform the homing operation (bit 11
in
= 1).
EXAMPLE
The main and default features of the SMAX linear encoder are as follows:
Default resolution
= 0.1 mm
MTAX-680 max. measuring length
= 600 mm
Max. number of information
= 6,000 (13 bits)
As stated, the number of information provided to output is calculated as
follows:
number of information =
measuring length
resolution
Thus, in a default configuration the number of information is:
number of information =
measuring length
=
600
=
6,000
resolution
0.1
Let's assume that you need 2,000 information to be provided for the max.
measuring length. It follows that you need to calculate and then set a custom
resolution.
MAN SMAX MB E 1.2
Programming parameters
60 of 84