SMAX MODBUS®
Wrong parameters list [0003 hex]
[Register 4, Unsigned16, ro]
The operator has entered invalid data and the
has been triggered. This variable is meant to show in detail (bit value = HIGH)
which parameter is wrong, according to the following table.
Please note that the normal work status can be restored only after having set
proper values.
Bit
Parameter
0
Not used
1
2
3
4
Operating parameters [0003 hex]
5
6
Serial com baud rate [0005 hex]
7 … 15
Not used
SW Version [0004 hex]
[Register 5, Unsigned16, ro]
This is meant to show the software version of the encoder.
The major number shows the firmware edition, while the minor number shows
the firmware revision.
The meaning of the 16 bits in the register is as follows:
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Ms bit
Ls bit
Major number
Minor number
Value 01 00 hex in hexadecimal notation corresponds to the binary
representation 00000001 00000000 and has to be interpreted as: firmware
edition 01, firmware revision 00.
MAN SMAX MB E 1.2
Programming parameters
71 of 84