SMAX MODBUS®
Save parameters
bit 9
Data is saved on non-volatile memory at each rising edge of
this bit; in other words, data save is performed each time
this bit is switched from logic level low (“0”) to logic level
high (“1”).
Load default parameters
bit 10
Default parameters (they are set at the factory by Lika
Electronic engineers to allow the operator to run the device
for standard operation in a safe mode) are restored at each
rising edge of this bit; in other words, the default
parameters uploading operation is performed each time this
bit is switched from logic level low (“0”) to logic level high
(“1”). The complete list of machine data and relevant default
parameters preset by Lika Electronic engineers is available
on page 81.
WARNING
The execution of this command causes all parameters which
have been previously set to be overwritten!
Perform counting preset
bit 11
It allows to perform a homing operation of the encoder. As
soon as the command is sent, the position value which will
be transmitted for the current position of the encoder is the
one set next to the
all the previous and following positions will get a value
according to it. Operation is performed at each rising edge
of this bit, i.e. each time this bit is switched from logic level
low (“0”) to logic level high (“1”). When this command is
sent, the current encoder position is temporarily saved in
the
information on the preset function and the meaning and
use of the related registers and commands
WARNING
To save the current encoder position in the
register permanently, please execute the
command. Should the power be turned off
lost!
bit 12 … 15
Not used.
MAN SMAX MB E 1.2
Programming parameters
67 of 84