SGSM
The magnetic ring 2 can be fastened to the main
shaft using the grub screws 5 type M4 x 5 min.
(Figure 4).
The acceptable gap between the sensor and the
magnetic ring is between 0,1 and 1,5 mm (Figure 5).
Prevent the sensor 1 and the magnetic ring 2 from
coming into contact.
4 - Electrical connections
Colour
Function
Yellow
A
Blue
/A
Green
B
Orange
/B
Red
+VDC
*
Black
0 VDC
*
see order code
SGSM-L-1-…
+VDC = +5VDC ± 5%
SGSM-Y-2-…
+VDC = +10VDC +30VDC
All sensors can provide inverted signals.
A = A signal
/A = inverted A signal (or complementary signal,
typically referred to as A NOT)
The whole range of magnetic sensors provides A, /A,
B, /B output signals. We recommend the inverted
signals always to be connected whenever the
receiving device can accept them. Otherwise each
output has to be insulated separately.
Connecting the output signals together and/or to
+VDC or 0VDC may cause permanent damage to the
sensor.
MAN SGSM I_E 1.2.odt
7
www.lika.it
www.lika.biz
Figure 4 - Fastening the magnetic ring
Figure 5 - Acceptable gap between sensor and ring
WARNING