SMA1
WARNING
Load and save default parameters
parameters which have been set previously are overwritten, thus previously set
values are lost!
As soon as the command is sent, the register is set back to "00" (
) automatically.
Wait min. 30 ms (EPROM writing time) before using a new function.
Default = 00 (
Configuration
[49, rw]
Bit
Function
bit=0
bit=1
0
Not used
1
Preset
Offset
2
Enable preset / offset Enable
Disable
3
Not used
4
Not used
5
Gray
Binary
6
*
Standard
Inverted
7
Not used
*
: it affects the absolute position information, not the sine/cosine signals
Set preset / offset
This parameter is available only if the
parameter is set to
ENABLE. It allows to activate either the preset function (
PRESET) or the offset function (
Offset value has to be set in the
register. After having enabled
the preset / offset functions (
= ENABLE), this item allows
to activate either the preset function or the offset function. The value set in the
register will have a different meaning depending on the value
of this parameter whether it is set to PRESET (0) or OFFSET (1). In the first case
(
preset value; while in the second case (
register is used to set the offset value. To activate the preset / offset
Save and activate Preset / Offset
register (set “02” in the register 48).
For any information on the preset and offset functions refer to the
Default = 0 (Preset)
Enable preset / offset
It enables / disables the preset / offset functions. After having enabled the use of
the functions you have to choose whether to activate the preset or the offset in
MAN SMA1 E 2.9.odt
7 - BiSS C-mode interface
36 of 48