SMRA - SSI and BiSS
4. To save the new Preset value, you must use the
register (set “01” in the
register).
5. Otherwise, to both save and activate the the new Preset value at the same
Save parameters and activate Preset
register (set “02” in the
register).
Function
ADDR
DATA Tx
40
01
Writing in the Preset
register
12
40
13
9C
40
00
function in the
register
77
01
or
function in the
register
77
02
Preset setting enable
[40, wo]
It allows the operator to enable the setting of the
allowed to set a new preset value only after having entered the value “01” next
to this
register. As soon as you have entered the desired
preset value, you must set the value “00” next to this
register and then save data.
Serial number
[60 … 63, ro]
These registers contain the serial number of the device expressed in hexadecimal
notation.
Register 60: year of production.
Register 61: week of production.
Registers 62 and 63: serial number in ascending order.
MAN SMRA SSI_BiSS E 1.2.odt