MC150
Setup for devices with RS232 serial interface
(option I1)
P60
Display address [11, 99]
Enter here the serial address of the readout when
using the serial interface option RS232. Don't use
addresses 20, 30, 40,….., 90.
Default value:
11
P61
Baud rate [0, 4]
0 = 2400
1 = 4800
2
= 9600
3 = 19200
4 = 38400
P62
RS232 mode [0, 3]
0
= RS232 protocol according to DIN66019
1 = Printer mode. To transmit actual value
periodically to a printer at a time interval set in
parameter
P63
.
2 = Printer mode. To transmit actual value to a
printer when pushing
E
button (attention to
P07
: do not use 1, 4 and 16 functions).
3 = Printer mode. To transmit actual value to a
printer when activating Input CON3/ pin 5
(attention: set
P12
= 0).
P63
Transmission time interval [0.01, 650.00]
Enter the time interval for periodic actual value
transmission in sec. (
P62
must be =1).
Default value:
1.00
P99
Actual value for RS232 [-99999, 999999]
This parameter shows the actual value for serial
transmission via RS232 Interface if parameter
P62
=0.
NOTE:
In order to activate modified parameters, switch off
and on the device.
8 - RS232 interface
8.1 PC connection
Use 9 pin DSub connector and connect with CON4
of the MC150 readout.
Pin
Function
1
RxD
Reception data
2
TxD
Transmission data
3
GND
Ground
Make sure that RxD on PC side is connected with
TxD on MC150 side and TxD / PC is connected with
RxD / MC150.
8.2 Technical data
Function
Data
Baud rate
2400,4800,
9600
,19200,38400
Data bits
8 bit ASCII
Parity bit
No
Stop bit
1
Flow control
No
8.3 Communication protocol
The RS232 protocol is according to DIN 66019, ISO
1765, ANSI X3.28.
The PC is the master and the MC150 is the slave
with individual serial address to be entered in
Parameter
P60
.
There are 3 ways of communication:
•
Send
•
Receive
•
Broadcast
MAN MC150 I_E 1.7