MC150

Setup for devices with RS232 serial interface 
(option I1)

P60

 Display address [11, 99]

Enter here the serial address of the readout when 
using the serial interface option RS232. Don't use 
addresses 20, 30, 40,….., 90.
Default value: 

11

P61

 Baud rate [0, 4]

0 = 2400
1 = 4800

2

 = 9600

3 = 19200
4 = 38400

P62

 RS232 mode [0, 3]

0

 = RS232 protocol according to DIN66019

1 = Printer   mode.   To   transmit   actual   value 

periodically to a printer at a time interval set in 
parameter 

P63

.

2 = Printer   mode.   To   transmit   actual   value   to   a 

printer when pushing  

E

  button (attention to 

P07

: do not use 1, 4 and 16 functions).

3 = Printer   mode.   To   transmit   actual   value   to   a 

printer   when   activating   Input   CON3/   pin   5 
(attention: set 

P12

 = 0).

P63

 Transmission time interval [0.01, 650.00]

Enter   the   time   interval   for   periodic   actual   value 
transmission in sec. (

P62

 must be =1).

Default value: 

1.00

P99

 Actual value for RS232 [-99999, 999999]

This   parameter   shows   the  actual   value  for   serial 
transmission   via   RS232   Interface   if   parameter 

P62

=0.

NOTE:

In order to activate modified parameters, switch off 
and on the device.

8 - RS232 interface

8.1 PC connection

Use 9 pin DSub connector and connect with CON4 
of the MC150 readout.

Pin

Function

1

RxD

Reception data

2

TxD

Transmission data

3

GND

Ground

Make sure that RxD on PC side is connected with 
TxD on MC150 side and TxD / PC is connected with 
RxD / MC150.

8.2 Technical data

Function

Data

Baud rate

2400,4800,

9600

,19200,38400

Data bits

8 bit ASCII

Parity bit

No

Stop bit

1

Flow control

No

8.3 Communication protocol

The RS232 protocol is according to DIN 66019, ISO 
1765, ANSI X3.28.
The PC is the master and the MC150 is the slave 
with   individual   serial   address   to   be   entered   in 
Parameter 

P60

There are 3 ways of communication:

Send

Receive

Broadcast

MAN MC150 I_E 1.7

14

www.lika.it

www.lika.biz

Содержание MC150 series

Страница 1: ...voltage power cables e g drive cables Install EMC filters on sensor power supply if needed Avoid mounting sensor near capacitive or inductive noise sources such as relays motors and switching power s...

Страница 2: ...Pin 4 N max 100 mA Pin 5 P E 5 2 CON2 connections sensor input Pin Function 1 GND 2 24Vdc J1 left power supply 24Vdc 12Vdc J1 left power supply 115Vac 230Vac 5Vdc J1 right any power supply 3 A 4 A see...

Страница 3: ...ss to setup menus Push F key to enter setup push to select Func 1 or Func 2 push E to scroll parameters push F to exit setup Admissible value range for each parameter is listed as follows min value ma...

Страница 4: ...estore default value see chapter Default parameter 6 2 1 P07 Function of the push buttons 0 6 The function of the and the E buttons in operating mode can be selected 0 no functions 1 E will set actual...

Страница 5: ...6 Output configuration 0 1 0 static output 1 with output dwell time see P17 and P18 P17 Output 1 dwell time 0 2 50 Enter output dwell time between 0 and 2 50 seconds P16 must be 1 Default value 0 P18...

Страница 6: ...ion in sec P62 must be 1 Default value 1 00 P99 Actual value for RS232 99999 999999 This parameter shows the actual value for serial transmission via RS232 Interface if parameter P62 0 NOTE In order t...

Страница 7: ...smission is correct slave replies with ACK in any other cases with NAK MC150 PC ACK or NAK All parameters sent to the slave are stored in a data buffer Parameters have to be activated by the activate...

Страница 8: ...the following data string will be transmitted MC150 printer AD1 AD2 DATA LF CR xx xx xx 0A Hex 0D Hex The MC150 is sending its serial address followed by the actual value and Line Feed LF and Carriage...

Отзывы: