LD120
F_rSt
[on, oFF] It enables the reset function (by pressing
*
key).
on
= function enabled
oFF = function disabled
*
= save,
P
= next parameter,
P
for 3 s. = exit
F_rEF
[on, oFF] It enables the datum function / Reference
(by pressing
*
key).
on
= function enabled
oFF = function disabled
*
= save,
P
= next parameter,
P
for 3 s. = exit
F_oFS
[on, oFF] It enables the offset function (by pressing
P
and
keys).
on
= function enabled
oFF = function disabled
*
= save,
P
= next parameter,
P
for 3 s. = exit
rEF
[-99999, 99999] Datum value, i.e. absolute reference
value for the measuring system. This value is
displayed by pressing
*
key for 3 seconds (displayed
value includes the set offset values).
Default value =
0
*
= save,
P
= next parameter,
P
for 3 s. = exit
OFS1
(-99999, 99999) First offset value Offset 1 (e.g. tool
correction). This value is added to the current value
(see 6.2.3).
Default value =
0
*
= save,
P
= next parameter,
P
for 3 s. = exit
OFS2
[-99999, 99999] Second Offset value Offset 2. This
value is added to the current value and to
Default value =
0
*
= save,
P
= next parameter,
P
for 3 s. = exit
OFS3
[-99999, 99999] Third Offset value Offset 3. This
value is added to the current value and to
Default value =
0
*
= save,
P
= next parameter,
P
for 3 s. = exit
NOTE
To set negative values, select sign digit with
key
and change with
key. If “
-
” sign flashes, the
negative value is selected; otherwise positive value
is selected. Press
*
key to save.
F_SAP
[on, oFF] It saves the last value displayed before
power off.
on = storage of last value enabled
oFF
= storage of last value disabled
*
= save,
P
= next parameter,
P
for 3 s. = exit
When the setup is accomplished the display shows
"
rESEt
".
Press
P
OFSx
.
Press
*
key to reset the display.
Press
P
key twice to exit setup.
6.3.3 Menu 2: RS-485
Ad xx
[00, 31] It sets the address of the device (only if
ordered with serial interface, -I4 order code).
Default value =
0
*
= save,
P
= next parameter
H_cnt
(1/10 h) Hourmeter. It shows the elapsed time
(display connected to power supply). Resolution is
1/10 hour (6 minutes).
= hourmeter reset,
P
= exit
7 - RS-485 serial interface
(-I4 order code)
If the display is provided with RS-485 serial
interface, the following commands can be used.
7.1 RS-485 parameters
Baud rate = 9600
Data bits = 8
Parity bit = No
Stop bit = 1
Flow control = Xon/Xoff
7.2 Serial commands
Serial commands must have the following structure:
| A D C M N D = X