ES58 • EM58 MODBUS®
Operating parameters [0008 hex]
[Register 9, Unsigned16, rw]
Operating parameters [0008 hex]
register:
byte
MSB
LSB
bit
15
…
8
7
…
0
msb
lsb
msb
lsb
Byte 0
Scaling function
bit 0
This bit is meant to enable / disable the scaling parameters
Custom counts per revolution [0000-0001 hex]
Custom total resolution [0002-0003 hex]
. When the
scaling function is disabled (bit 0 = 0), the encoder uses its
own physical resolution (i.e. hardware counts per revolution
and number of hardware revolutions, see the encoder
identification label); otherwise, when the scaling function is
enabled (bit 0 = 1), the encoder uses the resolution set next
to the registers
Custom counts per revolution [0000-
Custom total resolution [0002-0003
in accordance with the following relation:
Transmitted
position value
=
x Real position
≤
Hardware counts per revolution
The value that is currently set can be read in the
WARNING
Every time you enable/disable the
change the scaling values (see the
required to check and, if necessary, to set a new preset value
(see the
finally save the new parameters (see the
function).
MAN ESx58x_EMx58x MB E 1.3