AMM8A SSI & BiSS C-mode
Load and save default parameters
Default parameters are set at the factory by Lika Electronic engineers to allow
the operator to run the device for standard operation in a safe mode. As soon as
the command is sent, the default parameters are uploaded and activated. All
parameters which have been set previously are overwritten, thus previously set
values are lost. The complete list of machine data and the relevant default
parameters preset by Lika Electronic engineers are available on page 77. Set “04”
in the
register.
WARNING
Load and save default parameters
parameters which have been set previously are overwritten, thus previously set
values are lost!
Reset all warnings / errors
It resets the specified counters and all the active warning and error messages.
Set “08” in the
register.
Please note that, after resetting the warning or error message, if the problem
that caused the message to be triggered has not been solved, the warning or
error message will be invoked to appear again.
For the complete list of the available encoder error and warning messages,
please refer to the
For the complete list of the available sensor warning messages, please refer to
the
For the complete list of the available sensor error messages, please refer to the
Default = 00
Configuration
[49, rw]
register will be active immediately after
value permanently (set “01” in the register 48
).
Default = 60h = 0110 0000
2
Bit
Function
bit = 0
bit = 1
0 lsb
1
00 = Position information
10 = Speed information
01 = Acceleration information
2
Enable
Disable
3
Not used
-
4
Not used
-
5
Gray
Binary
6
CCW rotation
CW rotation
7 msb
Not used
-
MAN AMM8A SSI_BiSS E 1.10.odt
8 - BiSS C-mode interface
63 of 80