AMM8A SSI & BiSS C-mode
show the speed peak reached by the encoder. The speed peak can be reset by
setting “08” in the
register.
The speed value is expressed in RPM.
The speed is sampled every 7.8125 msec.; the system detects speed values up to
7,324 RPM and records them with increments of 1 RPM.
It is possible to set a speed peak warning limit next to the
registers. As soon as the speed value reaches the set peak limit, the
register is set to high (=”1”).
Register
66
67
MSB
LSB
2
15
… 2
8
2
7
… 2
0
Speed peak warning limit
[68–69, rw]
These registers allow to set a speed peak warning limit. As soon as the registers
66-67
reach the limit set in this item, the warning bit 2
(=”1”).
If the registers are set to =”00 00 00h”, then the speed peak warning limit
function is disabled and the registers 66-67
value. Any value greater than 0 will set the speed peak limit at which the
warning message will be invoked to appear; moreover the
show the speed peak reached by the encoder instead.
See also
Default = 00 00 00h
Encoder warnings and errors
[74, ro]
This register is meant to show the warning and error messages that are
currently active (the relevant bit = “1”) in the encoder. To clear the warning and
error messages, set “08” in the
register. Please note that, after
resetting the message, if the problem that caused the message to be triggered
has not been solved, the warning or error message will be invoked to appear
again.
Bit 0
Work cycles limit reached
The work cycles warning limit set next to the
registers has been reached. To clear the warning message, set “08” in the
register. Please note that, after resetting the message, if the work
MAN AMM8A SSI_BiSS E 1.10.odt