background image

 

 

 

 

www.lih.de

 S. 

1/3 

LIH14041969 

LIH UV Master Junior 250W skylight ECG symmetric medium beam 

 
 
 
 
 

 

 

 

 

 

Fig.1 Dimensions and possible positions 
 

 

Safety considerations for people and animals 

  The device LIH UV Master Junior 250W skylight does not only simulate sun in both 

UVA and UVB range; it also provides light at 10000K  with very good color rendition in 
the visible range. Additional light that may come e. g. through windows, roof lights or 
luminaires allows regulation of the UV dose over time, so the device may be switched 
off early, while the artificial day for the animals continues. If you operate the device 
without additional sources of light, it is essential to make sure that the maximum UV 
dose for the animals will not be exceeded. 

  UV radiation may cause serious burn injuries to people (sunburn) depending on their 

skin type. Protect your skin by appropriate clothing and sunscreen and wear glasses 
with protective lenses. UV Master Junior is not certified as a medical product for 
medical or esthetic treatment of human beings e. g. as a cure or tanning treatment. 

  A veterinarian or biologist must define time t and exposure level E 

UV-B

 for animals 

exposed to UV B radiation. 

  Areas free for visitors must not be exposed to UV radiation. 

  We recommend a cut-off mechanism at the door protecting animal keepers and other 

staff members from burn injuries. 

  Exposure ( H 

UV-B

 = E 

UV-B

 x t) defines the radiation effect. 

Rated power output 

250W 

Protection class 

IP66 

Protection type 

UV lamp 

LIH 250W UVA/UV B code14041970 

UV transparent glass 

Code 14041971 

Line voltage 

230V (standard) 220-240V (

with electronic ballast

Weight 12.4 

kg 