QoS 802.1p port limiting
– allows limiting bandwidths of priority queues on all three ports (LAN, WAN
and Mng) for both egress and regress directions. Possible choices are varying from 64Kbps to
88Mbps;
Pressing
Execute configuration
applies changes made to the corresponding section only for the local
side LigoPTP 24 FODU. If
Rollback on
is selected, configuration will be reverted in case of erroneous
configuration changes applied;
Write to config file
– writes to configuration file all the changes made on the whole page (command
line
– cfg write);
FODU returned
- in case of error or incorrectly entered parameter value, or other problems on the
whole page
– the info message is being shown here. Otherwise it says “Ok”.
SNMP Configuration
The SNMP configuration window provides the configuration of SNMP communities, host and trap
addresses.
Explanation of customization fields:
SNMP Community Configuration
Read
- Specifies the SNMP community name of the agent to enable parameters to be read (command
line
– snmp community read <communityname>);
Write
– specifies the community name of the agent to enable parameters to be written (command line
– snmp community write <communityname>);
SNMP trap address
– sets the IP address of the management terminal with the installed Trap
Manager software, based on SNMP platform. The LigoPTP 24 FODU management controller sends
SNMP traps to the Trap Manager with IP address specified here. The SNMP Trap Manager is a PC
with installed SNMP trap management software. The default Trap Manager IP address is
255.255.255.255 meaning that no trap packets are sent by the management controller (command line
– snmp trap <ipaddr>);